Operator Menu; Information Symbols - INTEGRA Metering AMFLO SONIC UFA-280 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operator menu

Menu 1
Flow volume totalizer 1.
Battery icon shows full.
Menu 3
Actual flow rate.
Negative values indicate reverse flow.
Menu 4
Failure information.
Each code indicates a specific failure.
F
No failure (normal indication)
F1
Track 1 not measuring
F2
Track 2 not measuring
F3
Internal failure
F4
Internal failure
F5
Battery low or power supply failure
F6
Flow overload
F7
Pulse freq. overload output A
F8
Pulse freq. overload output B
F9
Datalogger warning/alarm
Failure code combinations:
F12 is the equivalent of F1 and F2 simultaneously:
track 1 and track 2 are not measuring.
Display test
Check of all segments.
Display toggles between all segments on/off.

Information symbols

Status information symbols show actual status of important flow-
meter elements.
The warning/alarm symbol appears when ultrasonic sensors do
not measure or when a failure occurs according to menu 4. The
warning/alarm symbol disappears when problem is rectified.
Mains power supply symbol appears when mains power is connec-
ted to transmitter.
There are two symbols for battery charge status. „Battery full"
symbol indicates battery charge is above the warning level (6-year
hour counter).
„Battery low" symbol indicates that battery charge is below war-
ning level and battery should be replaced. „Battery low" symbol
indicates only that battery charge is below a pre-set level, not that
charge is zero. Flow measurement continues uninterrupted when
battery low symbol appears, until battery is completely drained.
AMFLO
SONIC UFA-280
®
Mains
Battery
Alarm
supply
status
31