Service
In order to locate and diagnose failures, a software tool for diagnosis and re-programming of outputs is available. Failure information is
available on the display. Failures are stored in memory, and can be accessed via infra-red communication port.
Installation
Installation of sensor compact/remote versions
Requirement for straight inlet before flowmeter
In order to maximise performance it is necessary to have straight inlet and outlet flow conditions before and after flowmeter.
Furthermore, a minimum distance between flowmeter and pumps and valves must be respected. It is also important to centre flowmeter in
relation to flanges and gaskets. Make sure that flowmeter is positioned as low as possible to prevent air from being trapped in
flowmeter at transducers.
Find a position on the pipeline where inlet pipe to flowmeter has a straight length as specified below.
Note:
For MID-approved FUE380 systems the following inlet pipe is recommend: L2 for ≥ sizes DN 80: 1.5 m
Single bend
Dual bend
22
1 x 90° bend
L2: Min. 10 x pipe diameter
L1: 3 x pipe diameter
2 x 90° bends in the same plane
L2: Min. 10 x pipe diameter
L1: 3 x pipe diameter
AMFLO
SONIC UFA-280
®