15. Maintenance and cleaning
IMPORTANT! BEFORE ANY MAINTENANCE OR CLEANING OPERATIONS ARE CARRIED OUT,
CUT OFF POWER SUPPLY TO THE CABINET BY MEANS OF THE MAIN SWITCH.
Food products can deteriorate due to germs and bacteria.
Respect of the rules of hygiene is indispensable to ensure the safeguard of consumer health and
respect of the cold chain.
Cleaning of the refrigerating cabinets is distinguished as follows:
Cleaning the external parts (Daily / Weekly)
- Clean all the external parts of the cabinet weekly using neutral detergents for domestic use or soap
and water.
- Rinse with clean water and dry using a soft cloth.
- DO NOT use abrasive products and solvents that may in any way alter the surfaces of the cabinets.
- DO NOT spray water or detergent on the electric parts of the cabinet.
- DO NOT use alcohol to clean parts in metacrylate (plexiglas).
Cleaning the internal parts (Monthly)
Cleaning of the inner parts of the cabinet aims at eliminating all of the pathogenic micro-organisms so
as to thus better protect the foodstuffs contained.
Before carrying out the inner cleaning of a cabinet or of a part of one:
- Empty it completely of all the foodstuffs it contains.
- Cut off power supply to the cabinet by means of the main switch.
- Unmount all the removable parts such as display trays, various grids, etc.
- Wash with warm water and detergent containing disinfectant, then dry carefully.
- Carefully clean the bottom tray and eliminate any foreign bodies that may have fallen onto the fan
holder casing through the intake grating.
- In the case of abnormal formation of ice, please call a Qualified Refrigerator Technician.
- Clean the drip pan and drain regularly lifting the fan casing if necessary.
To protect hands during this operation, wear working gloves.
Once the cleaning operations have been completed, re-mount all the removable parts (cleaned and
dried) and restore power supply. Once the internal operating temperature has been reached, the
products to be displayed can be replaced inside the cabinet.
Note: Make sure that fans, ceiling lights, electric cables and any other electric equipment are
wetted during cleaning.
16. Dismantling the cabinet
In accordance with the waste disposal regulations in each country and in respect of the environment
in which we live, please differentiate the parts of the cabinet so as to be able to dispose of them
separately or recycle them appropriately.
None of the parts that make up the counter can be disposed of together with urban solid waste,
except for the metallic components which, in any case, are not classified as special waste in most
European countries.
Materials used in the manufacture of the cabinet:
- Iron piping and sheet metal:
- Copper, Aluminium:
- Galvanized sheet metal:
- Foam polystyrene (R134a):
- Tempered glass:
- Wood:
- PVC:
- RIM:
- Polycarbonate:
THE COMPONENTS OF THE REFRIGERATING CIRCUIT MUST NOT BE CUT OR SEPARATED, BUT MUST
BE TAKEN INTACT TO CENTERS SPECIALISED IN RECYCLING REFRIGERATING GAS.
05060075 00 01/03/2007
lower frame, uprights, shelves
refrigeration circuit, electrical system and top strip
bottom panels, painted panels, base structure, shelves and trays
thermal insulation
glass sides
foamed tray side frames
bumper and handrail
coating on lower part of end pieces
fluorescent light casing and air outlet honeycomb