Troubleshooting
Possible Problem
The insert is not
venting out properly.
Filter is vibrating.
RF Remote control
does not work.
26
Possible Cause
Using the wrong size of ducting.
The insert might be hanging to
high from the cook top.
The wind from the opened
windows or opened doors in the
surrounding area are affecting
the ventilation of the insert.
Blockage in the duct opening or
ductwork.
Filter is loose.
Spring clip is broken on the filter.
Battery is dead.
Poor communication with the
insert.
RF Remote lost communication
with the insert.
Change the ducting to the correct size
Adjust the distance between the cooktop
and the bottom of the insert within 24"
to 36" for gas cooktops and 20" to 36"
for electric cooktops.
Close all the windows and doors to
eliminate the outside wind flow.
Remove all the blocking from the duct
work or duct opening.
Adjust or change the filter.
Change the spring clip.
Replace battery with type A23 12v.
Remote control must be within 15 ft of
insert.
Reset liner and remote by switching
power off at the circuit breaker for 5
minutes. Place remote on counter top
near the insert and switch the circuit
breaker back on.
Tornado Glo Use, Care, and Installation Guide
C O R E
TO R N A D O G LO
I N S E R T
Solutions