Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

www.zephyronline.com
Tornado Mini
AK8400AS
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
APR19.0501 © Zephyr Ventilation LLC.
READ AND SAVE THESE INSTRUCTIONS

Publicité

Table des Matières
loading

Sommaire des Matières pour Zephyr Tornado Mini AK8400AS

  • Page 1 Tornado Mini AK8400AS Model number: Serial Number: Date of Purchase: Sales Dealer: APR19.0501 © Zephyr Ventilation LLC. READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Specifications ............... Electrical ................. Installing the Power Pack ........FEATURES & CONTROLS Slide Controls ............... MAINTENANCE Cleaning and Installing Filters .......
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
  • Page 6: Parts Not Supplied

    www.zephyronline.com MODELS: AK8400AS PARTS SUPPLIED 1 - Power Pack 1 - Aluminum mesh filter 2 - Halogen light bulbs (pre-installed) 1 - Single internal blower (pre-installed) 1 - Hardware package HARDWARE PACKAGE CONTENTS Suction Cup (1) M4 x 1-1/2” (4) M4 x 1” (4) PARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) - Optional stainless steel liner (AK084xAS) - Optional Recirculating Kit (ZRC-8400A)
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8 www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 24”. For optimal performance, the recommended maximum mounting height should be no higher than 36”. It is important to install the hood at the proper mounting height.
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape. Some Ducting Options side wall cap w/ gravity damper side wall cap w/ gravity damper Soffit or crawl space...
  • Page 10 www.zephyronline.com 19-1/2” 12-1/8” 5-1/16” 10-5/8” 20-9/16” front 14-3/16” 9-15/16” 16-9/16” side...
  • Page 11 ELECTRICAL WARNING All Electrical work must be performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
  • Page 12 www.zephyronline.com CAUTION: At least two installers are ” required due to the weight and size of the hood. 1. Install optional AK084xAS Stainless Steel Liner. Review manual included with liner for more details. 2. If no liner is used cut out an opening in the bottom of the cabinet by following the dimensions in FIG 1.
  • Page 13 Blower On/Off Speed Selection Lights Bright/Dim/Off I I I BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. LIGHTS BRIGHT/DIM/OFF 0 is off, I is dim, and II is bright.
  • Page 14: Surface Maintenance

    www.zephyronline.com SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
  • Page 15: Ductless Recirculating

    DUCTLESS RECIRCULATING Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the power pack functions in air “purifying” mode rather than exhausting the air. Fumes and exhaust from cooking is drawn and filtered by a charcoal filter. The air is then purified and recirculated back into the kitchen. We recommend to always exhaust air outside of the home by employing existing or installing new duct work, if possible. The power pack is most effective and efficient as an exhaust unit. Only when the exhaust option is not possible should you use the power pack in recirculating mode.
  • Page 16: Replacing Light Bulbs

    Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise. Replacement bulbs are available at specialty lighting stores. Purchase type MR16 (GU-10) 35W halogen. For Zephyr part numbers please turn to page 16 of the manual.
  • Page 17 TROUBLESHOOTING PROCEDURES FOR TORNADO MINI Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 18 www.zephyronline.com DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B0023 Aluminum Mesh Filter (each) 50200054 Charcoal Filter (each) Z0F-C084 Optional Accessories Liner, 30” AK0840AS Liner, 36” AK0846AS Recirculating Kit ZRC-8400A Light Bulb MR16 GU-10 LED (each) Z0B0040 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 19 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below.
  • Page 20: Product Registration

    PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
  • Page 21 Tornado Mini AK8400AS Numéro de modèle : Numéro de série : Date d’achat : Détaillant : APR19.0501 © Zephyr Ventilation LLC. LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 22 www.zephyronline.com...
  • Page 23 CONSIGNES DE SÉCURITÉ ........LISTE DU MATÉRIEL ............INSTALLATION Feuille de calcul pour le conduit ......Hauteur de montage et espace libre ....Options d’installation pour le conduit ....Spécifications de la hotte ......... Électricité ............9 Installation du bloc d’alimentation ....10 COMMANDES Commandes par curseur .........
  • Page 24 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 25: Fonctionnement

    ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 26: Pièces Non Fournies

    www.zephyronline.com MODÈLES: AK8400AS PIÈCES FOURNIES 1 – Bloc d’alimentation 1 – Filtres de maille décoratifs 2 – Ampoules halogènes (préinstallées) 1 – Ventilateur interne simple (préinstallé) 1 – Trousse de quincaillerie CONTENU DE LA TROUSSE DE QUINCAILLERIE Ventouse (1) M4 x 1-1/2” (4) M4 x 1”...
  • Page 27 Longueur x Pièces de conduit Longueur x Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 6” circ. à 5 pi rect., droit rect. de 3-1/4" x 10" 6”, 7”, 8”, 10” 1 pi 6”...
  • Page 28: Conduit D'aération

    www.zephyronline.com La hauteur de montage minimale entre la hotte et la cuisinière ne devrait pas être moins de 24”. Pour des performances optimales, la hauteur de montage maximale recommandée ne doit pas dépasser 36 ”. Il est important d’installer la hotte à la hauteur de montage adéquate.
  • Page 29: Avertissement De Risque D'incendie

    AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée.
  • Page 30 www.zephyronline.com 19-1/2” 12-1/8” 5-1/16” 10-5/8” 20-9/16” devant dessus 14-3/16” 9-15/16” 16-9/16” côté...
  • Page 31 ÉLECTRICITÉ AVERTISSEMENT Tous les travaux électriques doivent être réalisés par un électricien quali é ou par une personne possédant l’expérience technique et le savoir-faire nécessaire. Pour votre sécurité, enlevez le fusible ou ouvrez le disjoncteur de circuit avant de commencer l’installation. N’utilisez pas de cordon prolongateur ou de che d’adaptation avec cet appareil.
  • Page 32 www.zephyronline.com ATTENTION : Au moins deux ” installateurs sont requis compte tenu du poids et des dimensions de la hotte. 1. Installez le revêtement de protection en acier inoxydable optionnel AK084xAS. Consultez le manuel du revêtement pour de plus amples détails.
  • Page 33: Ventilateur Marche/Arrêt Choix De Vitesse

    Ventilateur Marche/Arrêt Choix de vitesse Lumières Fortes/Veilleuse/Éteintes I I I VENTILATEUR MARCHE/ARRÊT CHOIX DE VITESSE À 0 le moteur est éteint, I correspond à la basse vitesse, II à la vitesse moyenne et III à la haute vitesse. LUMIÈRES FORTES/VEILLEUSE/ÉTEINTES À...
  • Page 34: Entretien Des Surfaces

    www.zephyronline.com ENTRETIEN DES SURFACES : Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces.
  • Page 35: Configuration Sans Conduit D'aération

    CONFIGURATION SANS CONDUIT D’AÉRATION La configuration sans conduit a été conçue pour les endroits où l’échappement d’un conduit d’aération ne peut être installé. Lorsque transformé, le bloc d’alimentation fonctionne comme un système de « purification d’air » plutôt que comme un système d’échappement d’air. Les vapeurs et fumées de cuisson sont aspirées et filtrées par un filtre à charbon.
  • Page 36: Remplacement Des Ampoules

    Les ampoules de remplacement sont disponibles dans les magasins spécialisés en éclairage. Procurez- vous des ampoules halogènes de 35W de type MR16 (GU-10) . Consultez la page 16 du présent guide pour obtenir les numéros de pièces Zephyr.
  • Page 37 DÉPANNAGE POUR LES HOTTE TORNADO MINI Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée. l’appareil ne 2. La ligne électrique et le connecteur d’arrimage 2. Vérifiez que le branchement de l’appareil a été fonctionne pas.
  • Page 38 www.zephyronline.com DESCRIPTION Nº DE PIÈCE Pièces de rechange : Ampoule MR16 (GU10) 35W (chaque) Z0B0023 Filtre de maille métallique (chaque) 50200054 Filtre à charbon (chaque) Z0F-C084 Accessoires facultatifs : Revêtement de protection,30” AK0840AS Revêtement de protection,36” AK0846AS Ensemble de reprise d’air ZRC-8400A Pour commander des pièces, visitez-nous en ligne au http://store.zephyronline.com ou communiquez avec nous par téléphone au 1.888.880.8368...
  • Page 39: Agrafez Votre Reçu Ici

    Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
  • Page 40: Enregistrment Du Produit

    ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente.

Table des Matières