►►8. DISPLAY ERRORS
en
See B Fig. 3
it
ERROR
de
F0
1. The "ON/OFF" switch is turned
es
"ON" (|) when the heater is plugged
in
fr
nl
F1
1. No fuel
pt
da
2. Fuel is contaminated
fi
no
3. Photocell is dirty or damaged
sv
4. Fuel filter is dirty
5. Ignition error
pl
ru
F2
1. Interrupted cable
2. Sensor is damaged
cs
hu
F3
1. Internal heater overheating
sl
2. Antitilting sensor intervent
tr
hr
F4
1. Incorrect voltage
lt
LO
1. External temperature below -5°C
lv
CH
1. Continuous operation
et
►►9. PREVENTIVE MAINTENANCE SCHEDULE
ro
WARNING: BEFOR INITIATING ANY REPAIR OR MAINTENANCE PROCEDURE UNPLUG
sk
THE FEEDER CABLE AND MAKE SURE THAT THE HEATER IS COOLED DOWN.
bg
COMPONENT
Fuel tank
uk
bs
Nozzle
el
Photocell
zh
Fuel filter
Ignition device
Fan blades
CAUSE
TEMPERATURE CONTROL SENSOR ERROR
MAINTENANCE FREQUENCY
Clean every 150-200 hours of
operation or when necessary
Clean or replace once per season or
when necessary
Clean once per season or when
necessary
Clean or replace twice per season or
when necessary
Clean or replace every 1.000 hours
of operation, or when necessary
Clean when necessary
OPERATION ERROR
1. After disconnecting the heater, see that
the switch is in the "OFF" (0) position,
plug the heater in and turn the switch
"ON" (|)
PHOTOCELL ERROR
1. Turn the switch "OFF" (0), refill the fuel
tank
2. Turn the switch "OFF" (0) empty and
refill the fuel tank. Clean the filter using
clean fuel, do not damage the filter (SEE
PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
1. Contact the technical service center
2. Contact the technical service center
THERMOSTAT ERROR
1. Turn the heater off, wait until it is cooled
down
2. Place the heater on a level and stable
surface
INCORRECT VOLTAGE
1. Check voltage of your electric supply
system
1. Normal condition
1. Normal condition

MAINTENANCE PROCEDURE

Empty and rinse with fresh fuel
Contact the technical service center
Contact the technical service center
Clean the fuel filter with clean fuel
Contact the technical service center
Contact the technical service center
SOLUTION