USER'S MANUAL.
PROMAX-10
f)
AUTO POWER OFF
This field permits to activate (ON) or deactivate (OFF) the POWER-OFF function.
When this function is ON, the unit automatically turns off when it has remained
inactive for a period of 10 minutes.
g) BEEP
This function permits to activate (ON) or deactivate (OFF) the
beeper. When it is on, it sounds on pressing any key or when turning the rotary
selector in order to alert the user.
h) LANGUAGE
This field permits to select the language between: SPANISH, FRENCH, POLISH,
ENGLISH and GERMAN.
i)
EXTERNAL UNITS POWER SUPPLY (VLNB)
PROMAX-10
By means of the
to feed external units (MMDS antennas Multichannel Multipoint Distribution Service
in case of terrestrial television without cable wireless cable) by the signal service
connector.
This voltage will have to be provided externally by the power input [4] and to be
included in the margin from 21 to 25 V, in opposite case the instrument will not allow to
activate this function, displaying the message "Error VEXT " at the moment of the
configuration.
The activation or deactivation of VLNB takes place according to the described
process next:
-
Press repeatedly the key CONFIG until acceding to the second screen of
the configuration menu.
-
Turn the rotary selector until appears shaded line VLNB.
-
Press the rotary selector to activate the selection. Turning the rotary
selector, this one goes successively of OFF to ON.
-
Finally, to press the rotary selector to activate the configuration changes.
When surpassing the maximum LNB current consumption the output feeding
will be deactivated and LED (V
reactivate again the LNB voltage, after solving the cause of malfunction, it must be
access again to the instrument configuration according to the sequence previously
described.
Before using the LNB feeding function make sure of absence of other power
supplies in the measurement/power supply connector like DC / AC voltages.
The
entrance
of
PROMAX-10
SE, can produce damages in the implied equipment.
07/2011
SE
SE
it is possible to provide the voltage necessary
) from frontal will blink during a minute. In order to
LNB
external
voltages
PROMAX-10
when
trying
to
feed
SE
ATTENTION
from
the
Page 17

Publicité

loading