USER'S MANUAL.
PROMAX-10
4.2.6.1
Datalogger configuration.
From
the
LOGGER
when pressing the CONFIG key [14] we
will access to the configuration menu.
This menu permits to modify the THRESHOLD and
MEASURES parameters. To access to them turn
the rotary selector and once the parameter we want
to change is appears shadowed, press it; then
turning it its value will be modified. Finally
press it again to validate the new value.
a) THRESHOLD: It activates / deactivates the measurement threshold.
This parameter allows to carry out the logger function in an agile way, by
activating only those measures we consider significative.
In the OFF mode (deactivated) all measurements are taken (with a level
higher than 20 dBµV). On the other hand, when a level is defined, only
those channels with a level higher than the THRESHOLD value will be
measured.
b) MEASURES: It defines the types of measurements to be made.
This parameter allows to select the measurements that are desired to made
between:
Level
LEVEL / POWER
Yes
AV - C/N / MER
Yes
AV-CN / MER-
Yes
BER
(*) Note:
The BER measurements represent an increase of the data acquisition time.
To leave the configuration menu of the DATALOGGER mode, just press the key of
the operating mode you wish to access.
07/2011
SE
mode,
ANALOGUE CHANNELS
Audio /
Carrier /
Video
Noise
Ratio
Ratio
-
Yes
Yes
Yes
Yes
Figure 53.- Logger configuration menu.
DIGITAL CHANNELS
Power
-
Yes
Yes
Yes
MER
BER
-
-
Yes
-
(*)
Yes
Yes
IMPORTANT
Page 43