Installation considerations:
•
For best results, this valve should be installed by a licensed professional plumber.
•
Large pressure differences between the hot and cold supplies should be balanced for
proper operation of the valve.
•
Before beginning the installation, read the instructions thoroughly. Inspect the product,
and be sure that all parts are present and in good condition.
•
If you have questions or concerns regarding this installation, please contact Hansgrohe
Technical Services at 800 334 0455.
•
Rough valve 06624000 does not include service stops. If stops are required by lo-
cal plumbing code, order the stops separately (item #06900003) or use rough valve
06628000.
•
This ThermoBalance III rough valve is for use in a three-function shower
only. All outlets must be plumbed. Do not plug any outlet.
•
If a two-function shower with a shared function is desired, follow the
special piping instructions on page 5.
•
The ThermoBalance III rough requires a ThermoBalance III trim kit. Do not attempt to use
any other trim kit.
•
Do not attempt to use this valve with a diverter tub spout.
Technical Information
Recommended water pressure
Max. hot water temperature
Recommended hot water temperature
Nominal capacity @ 45 psi
Nominal capacity@ 60 psi
Safety stop
Max. output temperature
½" NPT connections
Listed by IAPMO
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
**The high temperature limit stop may be reset to comply with local plumbing codes. Refer to the trim kit installations.
45 – 72 psi
165°F*
120°F – 140°F*
6 gpm
7 gpm
100°F
110°F**
English
3