English
All models: Install the carrier plate and gasket
with the carrier plate screws.
Press the escutcheon firmly over the carrier plate.
The strips of Duotec will interlock, producing a
very firm hold.
Install the handle. Tighten the handle screw with
a 3 mm Allen wrench. The handle screw must
engage the slot milled into the brass on the bottom
of the cartridge.
Set the high temperature limit stop (optional) – see
page 11.
Justify the handle.
Justify the handle
Tools required:
Thermometer
3 mm Allen wrench
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the output
water is 100°F.
Turn the water off.
Use a 3 mm Allen wrench to loosen the handle set
screw. Remove the handle from the valve (1).
2
Hold the handle lever in one hand. With the
other hand, turn the temperature control knob
approximately ½ turn clockwise (2a). Then,
without pressing inward on it, turn it counter-
clockwise until it is positioned vertically and hits
the safety stop (2b).
Install the handle (3). Tighten the screw.
a
b