Télécharger Imprimer la page

Lotus F45-78ET Instructions Pour L'installation Et L'emploi page 19

Friteuses electriques

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 90/396. The
installation must be done observing the norms in force particularly concerning room ventilation and discharging gas
emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
MODELS
DIMENSIONS cm
80x90x70h
F45-78ET
The data plate is on the side (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible. It is
advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, in force.
The appliance is supplied without the connection cable.
To install the power supply cable, proceed as follows:
Remove the back panel
Push the connection cable through the cable blocked, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
Block the cable with the cable blocked, and reassemble the back panel. The earth wire must be longer than the
others so that if the cable blocked should break, it will disconnect after the tension wires.
N.B. The connection cable must have the following characteristics: it must be at least type H05 RN-F (resistant to a
temperature of at least 150°), and must have an adequate section for the power of the appliance (see technical data
table).
GB
DECLARATION OF COMPLIANCE
TECHNICAL DATA TABLE
POWER SUPPLY
400Vac/3N 50/60Hz
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
IE
MAXIMUM
ABSORBTION A
57,97
(28,99 + 28,99)
19
POWER SUPPLY
MAXIMUM
CABLE
POWER kW
(Silicone)
40
2
5x4 mm
(20 + 20)
2
+ 5x4mm

Publicité

loading