(11) Next, depress the Push Lever against the workpiece.
Now pull the Trigger.
□ THE NAILER MUST OPERATE.
(12) If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.
□ THE NAILER MUST OPERATE PROPERLY.
ADJUSTING AIR PRESSURE
Adjust the air pressure at recommended operating
pressure 70–120 psi (4.9–8.3 bar 5–8.5 kgf/cm
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
LOADING NAILS
● When loading nails into Nailer,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
<NR83A5 / NR83A5 (S) / NR83A5 (Y) / NR83A5 (S1)>
The nail loading procedure and precautions are the same
for the NR83A5 and NR83A5(S) with Steel Magazine
and for the NR83A5(Y) and NR83A5(S1) with Aluminum
Magazine, so in the following instructions, the NR83A5 is
shown as an example.
(1) Pull the nail feeder back until it latches
WARNING
● Do not exceed
120 psi (8.3 bar
8.5 kgf/cm
WARNING
Nail Feeder
(2) Insert nail strips one by one from above the magazine.
Two strips can be loaded at one time.
(3) Press the stop lever and slide the nail feeder forward
until it contacts the nail strip.
).
2
)
2
NOTE:
● Quietly push the Nail Feeder against the nail.
If the Nail Feeder is released from backward the
magazine and bumped against the nail, the
connecting plastic of the nail can be damaged.
● Use nail strip at least 5 nails remaining.
● Set heads of nails overlapped as shown in the below
fi gure.
Nail Strip
Magazine
Nail Feeder
Stop Lever