Step 4: Gas Requirements and Hookup
CAUTION:
When connecting unit to propane gas, make
certain the propane gas tank is equipped with
its own high pressure regulator in addition to
the pressure regulator supplied with the appli-
ance. The pressure of the gas supplied to the
appliance regulator must not exceed 14" wa-
ter column.
All manuals and user guides at all-guides.com
10
CAUTION
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig
(3.5kPa.).
"The appliance and its individual shut off valve
must be disconnected from the gas supply
piping system during any pressure testing of
the system at test pressures in excess of 1/2
psig (3.5kPa.)."
When checking the manifold gas pressure,
the inlet pressure to the regulator should be at
least 6.0" W.C. for natural gas or 11.0" for
propane.
Do not attempt any adjustment of the pres-
sure regulator.