OPERATING INSTRUCTIONS
6.3
Setting
en
6.4
Additional functions
34
O P E R A T I N G I N S T R U C T I O N S | GTB20
D
Setting range switching threshold for background suppression
Check the function as described in
behave as described in
see table 6, page
Sensing range setting
The sensing range is adjusted with the potentiometer (type: Multiturn, 7 rotations).
Clockwise rotation: sensing range increased; counterclockwise rotation: sensing range
reduced. It is recommended to place the object within the sensing range, e.g. see
table
11. Once the sensing range has been adjusted, the object is removed from the
path of the beam, which causes the background to be suppressed. The digital output
changes [see
table 6
and
table
Adjustable sensing range: 100 mm ... 3000 mm.
white background (90%)
x
y
Table 11: Sensing range setting
The sensor is adjusted and ready for operation.
Time functions
Time function setting
Time delay selector switch can be set on the device according to
see table 6, page
30. If the digital output fails to
30, check the application conditions.
9].
see table
1.
8026846.1K1C/2023/06/07 | SICK