Gas conversions
Gas conversions (from Natural gas to L.P . gas; or from L.P .
gas to Natural gas) must be done by a qualified installer.
WARNING
Shut off gas supply line valve.
Make all conversions before turning gas supply
valve back on.
Failure to follow these instructions can result in
explosion, fire or other injury.
L.P . gas conversion
1.
Complete installation sections A-C (Pages 7-8)
before converting cooktop to L.P. gas. Check that main gas
supply line has been shut off and the power supply cord is
disconnected.
2.
Remove burner grates.
pressure
regulator
pressure
regulator
Nat. gas
DO NOT REMOVE THE PRESSURE REGULATOR.
3.
Open broiler drawer to locate pressure regulator.
Pressure regulator: Remove plastic cover. Turn cap marked
"N" on front of pressure regulator counterclockwise with a
Page 12
All manuals and user guides at all-guides.com
Fire Hazard
Natural
plastic
cover
L.P .
plastic
cover
cap
washer
L.P . gas
wrench to remove. Do Not disturb or remove the spring
beneath the cap. Turn the cap over and reinstall cap on
regulator so that the letters "L.P. " are visible. Replace plastic
cover over cap.
air shutter
4.
Cooktop burners: Lift up cooktop maintop until it is
held in place by support rods. Remove shipping screws from
each burner. Remove burners.
orifice spuds
NAT
L.P .
L.F.
L.R.
5.
Locate L.P. gas orifice spuds in a literature package
included with the range. All L.P. gas orifice spuds are
stamped with "66" . Remove Natural gas orifice spuds using a
3/8" combination wrench. Install L.P. gas orifice spuds to
replace the Natural gas orifice spuds.
Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package. Reinstall burners.
Lower maintop to operating position. Reinstall burner
grates.
shipping
screw
burner
Remove and
replace orifice
spuds.
notches
gas
manifold
R.F.
R.R.

Publicité