Checking the gas broil ignition and flame (gas range
only)
NOTE: The oven door(s) must be installed and closed.
1. Turn on the main oven mode knob and the oven
temperature knob to BROIL.
The hot-surface igniter will attempt to light the
broiler after approximately 45 to 90 seconds, as
the safety valve coil heats to open. Once the air
has been purged from the gas supply line, the
broiler should light within four (4) seconds.
Observe the broil flame performance through the
oven door window. The ceramic tiles of the burner
should glow red hot (infrared) after several
minutes of operation. If after several minutes with
the burner lit, the broiler only has a small amount
of red glow (and burns mostly with blue flame
floating on the burner surface), check that the
broiler orifice is aligned to the center of the
burner tube inlet.
2. Repeat for the auxiliary oven, if applicable.
3. If the broil burner burns satisfactorily, reassemble the
backguard onto the appliance (see page 15 ).
Checking the gas bake ignition and flame (gas range
only)
NOTE: The oven door(s) must be installed and closed.
1. Install the front panel (see page 16 ).
2. Turn the main oven mode knob to BAKE and the oven
temperature knob to any setting.
The hot-surface igniter will attempt to light the
burner tube after approximately 45 to 90 seconds,
as the safety valve coil heats to open. Once the air
has been purged from the gas supply line, the
burner should light within four (4) seconds.
Observe the bake burner flame through the slots
in the bottom front panel. Look for considerable
"yellow tipping," noting that some small amount
of yellow tipping is normal in the flame
characteristics of burners running with propane
(LP) gas, flame lifting, or lazy flames.
3. Repeat for the auxiliary oven, if applicable.
4. If the bake burner burners perform satisfactorily,
reinstall the kick panel (see page 16 ).
22
Placing the conversion label
1. For proper identification and evidence of the
appliance's conversion for propane (LP) gas operation,
affix the provided conversion label in a location next
to the rating labels on the appliance.
Pro Grand conversion label placement
Pro Harmony conversion label placement