Service and Maintenance
Do not allow the machine to become contaminated.
․
Remove dust from the air vents with air compressor, vacuum or a soft brush.
․
Only use a damp cloth to clean the casing.
․
Before storing run distilled water through the system to help avoid condensing the
․
pump or heater.
․
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
Excessive dust, liquid and dirt built up will degrade performance and cause
․
overheating.
Fuse Replacement
Disconnect AC power before replacing the fuse. Only replace the fuse with
same type and rating.
Step 1: Disconnect the power cord from the supply.
Step 2: Use a flat-head screwdriver to release the fuse holder.
Step 3: Replace the fuse with exact same type and rating as indicated below.
Step 4: Reinsert fuse holder.
Fuse
120V = T10A 250V
240V = T7A 250V
All manuals and user guides at all-guides.com
11