DMX Operation
Making the DMX Connection – Connect the machine to a DMX controller or to one of the
machines in the DMX chain. The machine uses a 3-pin or 5-pin XLR connector for DMX
connection, the connector are located on the front of the machine.
DMX Channel Function
Channel Mode
2
1
Sync
Fluid
Only use Antari FLG water-based liquid for the Z-380 Fazer. The machine is tested and
calibrated with this liquid to get the best output performance. Warranty will be voided if any
other type of liquid is used, improper use of liquid may lead to machine failure and
malfunction.
All manuals and user guides at all-guides.com
Channel
1
2
1
1
10
Value
Function
0-5
Faze off
6-255
Faze 1-100%
Faze off
0-5
Fan 100%
Faze 1-100%
6-255
Fan 100%
Faze Off
0-5
Fan 20%
Faze 1-100%
6-255
Fan 21 – 100%