Performance data
Operating pressure of water (using standard nozzle)
Max. excess operating pressure (safety valve)
Water flow (can be regulated in a phase-less manner)
Suction of detergent (can be regulated in a phaseless
manner)
Water connection
Min. feed volume
Feed pressure (min.)
Max. feed pressure
Electrical connection
Current type
Frequency
Voltage
Connected load
Electrical protection (slow)
Type of protection
Protective class
Maximum allowed net impedance
Power supply
Temperature
Max. feed temperature
Max. operating temperature of hot water
Max. temperature safety thermostat
Temperature increase during maximum water flow
Gross heating performance
Chimney draught
Gas connection values
Natural gas E (G 20)
Natural gas LL (G 25)
Rated connection pressure (natural gas)
Propane
Rated connection pressure (Propane)
Environment data
Rated utilisation level
Standard emission factor NO
Standard emission factor CO (natural gas G 25)
Values for chimney dimensions
Suitability for excess pressure (min.)
Draught requirements
Exhaust flow - full load
CO
(Natural gas)
2
CO
(Propane)
2
Exhaust temperature max./min.
Combustion air/ air supply
Condensate drain-out
Condensate drain-out (max.)
Connectiing piece
Minimum water column, siphon
All manuals and user guides at all-guides.com
Technical specifications
MPa (bar)
MPa (bar)
l/h (l/min)
l/h (l/min)
l/h (l/min)
MPa (bar)
MPa (bar)
--
Hz
V
kW
A
--
--
Ohm
mm
°C
°C
°C
°C
kW
kPa
m
m
kPa
kg/h
kPa
%
(natural gas G 25)
mg/kWh
X
mg/kWh
kPa
kPa
kg/h
%
%
°C
Max. length: 10 n with two 90° arches (min. diameter 100 mm) From the in-
stallation room or fresh outside air - depending on the local regulations.
l/h
DN
mm
HDS 9/16-4
HDS 9/16-4
ST Gas
ST Gas LPG
1.251-108
1.251-109
16 (160)
16 (160)
18,5 (185)
18,5 (185)
500-1000 (8,3-
500-1000 (8,3-
16,6)
16,6)
0-50 (0-0,8)
0-50 (0-0,8)
1100 (18,3)
1100 (18,3)
0,1 (1)
0,1 (1)
0,6 (6)
0,6 (6)
3N~
3N~
50
50
380-420
380-420
6,4
6,4
16
16
IPX5
IPX5
I
I
(0,381+j
(0,381+j
0,238)
0,238)
5 x 2,5
5 x 2,5
2
30
30
98
98
110
110
60-65
60-65
75
75
0,01-0,04
0,01-0,04
/h
7,2
--
3
/h
8,2
--
3
1,8-5
--
--
5,7
--
5-6
97
97
< 40
--
< 40
--
0,05
0,05
0
0
130
130
9,5
--
--
12
190/150
190/150
4 (via siphon
4 (via siphon
into the drain-
into the drain-
age system)
age system)
40 (HTR)
40 (HTR)
300
300
7
-
EN
HDS 12/14-4
HDS 12/14-4
ST Gas
ST Gas LPG
1.251-110
1.251-111
14 (140)
14 (140)
18,5 (185)
18,5 (185)
600-1200 (10-
600-1200 (10-
20)
20)
0-60 (0-1)
0-60 (0-1)
1300 (21,7)
1300 (21,7)
0,1 (1)
0,1 (1)
0,6 (6)
0,6 (6)
3N~
3N~
50
50
380-420
380-420
7,5
7,5
20
20
IPX5
IPX5
I
I
--
--
5 x 2,5
5 x 2,5
30
30
98
98
110
110
60-65
60-65
95
95
0,01-0,04
0,01-0,04
9,8
--
11,4
--
1,8-5
--
--
7,2
--
5-6
97
97
< 40
--
< 40
--
0,05
0,05
0
0
166
166
9,5
--
--
12
170/130
170/130
4 (via siphon
4 (via siphon
into the drain-
into the drain-
age system)
age system)
40 (HTR)
40 (HTR)
300
300
29

Publicité

loading

Ce manuel est également adapté pour:

Hds 9/16-4 st gas lpgHds 12/14-4 st gasHds 12/14-4 st gas lpg