A-001
Fusioneret 3 man. tegn. til 1
A-
Rev.
A
B
C
30°
D
30°
switch calibration:
E
1. Stop the system by pressing relevant button on
the control display (refer to the image below).
F
110002491
No:
MAN. TEGN. FLOWSENSOR M. RØR
Desc:
Initials:
Drawn by:
AMT
G
AKS
Last rev. by:
Approved by:
AMT
Material:
1
Thickness (mm):
CONFIDENTIALITY NOTICE ! THIS DRAWING AND INFORMATION CONTAINED HEREIN ARE THE EXCLUSIVE PROPERTY OF NILFISK FOOD
2. Set the "rinse/foam" handle to foam position.
3. Turn the brass screw at the bottom until two
green LED light up.
4. Turn the screw counter clockwise until one of the
green LEDs light up.
5. Close the water supply and verify that the red
diode lights up. If not, repeat from step 4.
8.3.3. Pump/motor
•
No maintenance needed.
•
For further information see pump suppliers in-
struction manual.
8.4. Preventive/regular maintenance
Depending on usage, the following maintenance
should take place atleast once a year in order to pre-
vent defects and operational failures.
8.4.1. Coupling
•
Lubricate all coupling parts regularly (once a
month) with waterproof grease to prevent leaks
and o-ring damage.
•
If the unit has a spray gun, lubricate the gun's
o-ring.
•
Replace o-rings in leaking quick couplings.
•
24-01-2023
24-06-2019
Description
Date
8.4.2. Internal cleaning of the unit
Flow
•
•
•
Mark
110002491A
A-001
Review or Prototype
Rev:
Status:
Date:
28.02.2012
24-01-2023
28.02.2012
Color:
Tolerance:
DS/ISO 2768-m (medium)
Weight (g): 0,308
AKS
Admin
Mod. By
A
B
Internal cleaning of the unit is recommended
once a year, depending on the environment
where it is installed.
Avoid spraying inside the unit.
It is recommended to regularly check all product
C
hoses approximately once every three months.
D
E
F
Ver. 3.00
A4
Sheet size:
Scale:
1:2
Sheet:
1 of 1
34