Option D, No waste disposer - with air gap
No waste disposer — with air gap
~ Large silver drain
hose clamp
>
Rubber hose
connector
Drain hose
Connect black end of drain hose to
air gap and cut if needed.
NOTE: Do not cut ribbed section.
Attach drain hose to air gap with
large silver drain hose clamp
(provided). Use pliers to squeeze
clamp open and move into position.
lf the drain hose was cut, use a 11%"
to 2" (3.8 to 5.1 cm) screw-type
clamp (not provided).
Use a rubber hose (not provided)
with screw-type clamps (not
provided) to connect from waste tee
to air gap.
Install moisture barrier
(under a wood countertop)
|
Moisture
barrier
1.
Make sure the area under the cabinet is clean and dry for
installation of the moisture barrier.
2.
Remove the backing of the moisture barrier and apply to
underside of the countertop along the front edge of the
counter.
ES
op omy
a p r , gre, wp gm,
Us
genlyea.
so
apr
gen ben
Prepare Disnwasher
AWARNING
Tip Over Hazard
Do not use dishwasher until completely installed.
Do not push down on open door.
Doing so can result in serious injury or cuts.
AWARNING
Excessive Weight Hazard
Use two or more people to move and install
dishwasher.
Failure to do so can result in back or other injury.
1 | Put dishwasher on its back
Helpful Tip: Place cardboard under dishwasher until installed in
cabinet opening to avoid damaging floor covering. Do not use
door panel as a worktable without first covering with a towel to
avoid scratching the door panel.
Using 2 or more people, grasp sides of dishwasher door frame
and place dishwasher on its back.
2 | Remove panel and fasteners
¢
SS
j
o
|
Using a flat-blade screwdriver, turn the plastic fasteners /% turn to
unlock them. Remove panel. Do not remove tech sheet from
access panel.
11