9.2- UP end limit re-adjustment: (Only in case of manual
setting (awnings without blockers for UP end limit))
1- Move the motor to the UP end limit previously set in section 2.3
with the UP key.
2- Press simultaneously for 5 seconds the UP and DOWN keys,
the motor will jog in both directions.
3- Move to the new position with the UP and DOWN keys.
4- Confirm the new position by pressing 2 seconds the STOP key.
The motor will jog in both direction.
The new end limits setting is memorized.
10
Cancelling the programming
10.1
- Switch off the12V power supply to the motor for 2 seconds.
- Switch the 12V power to the motor back on for 7 seconds.
- Switch off the 12V power supply to the motor for 2 seconds.
- Switch the power to the motor back on.
If the motor is on the end limit position (up or down), the motor jogs,
otherwise, the motor runs for 5 seconds in random direction.
The motor is now in the "cancelling" mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must "cancel"
out of this mode all the motors which you do not want to reset by sending a command from their individual control
transmitter (UP or Down).
10.2- Then, confirm the cancelling of the concerned motor from the
individual control:
- Press the "PROG" key of the transmitter more than 7 seconds. Maintain
the pressure until the motor will first run for a half a second in one direction
and then the other, and a few second later, it will run again in both directions.
The motor returns to its initial settings. All transmitters and motor
settings are deleted and reprogramming is required.
11
Recording / controling / deleting intermediate position
Recording:
1-
- Move the motor to the wished position.
- Press 5 seconds on the STOP key until the motor jogs in both directions.
Controlling:
2-
- Press on the STOP key for 0,5 second. The motor goes to the intermediate
position.
Cancelling:
3-
- Press on the STOP key for 0,5 second, the motor goes to the intermediate
position.
- Press 5 seconds on the STOP key until the motor jogs in both directions.
The intermediate position is deleted.
SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions and used as intended according to these instructions is in
compliance with the essential requirements of the applicable European Directives and in particular of the Machinery Directive 2006/42/EC, and the Radio Directive
2014/53/EU. The full text of the EU declaration of conformity is available at www.simu.com. Emmanuel CARMIER, general director, GRAY, 07/2017.
6/6
1-
3-
OFF
ON
2s
7s
PROG ≥ 7s.
2s.
1-
2-
0,5s.
3-
0,5s.
2-
5s.
4-
2s.
OFF
ON
2s
5s.
7s.
5s.
5s.

Publicité

Table des Matières
loading

Table des Matières