ÉPIX™ Strip 2.0 QRG
Addressing Of Each Output When Using Art-Net™
When using Art-Net™, set the addressing for each of the 4 outputs of the ÉPIX™ Drive
642 , including: Net, Subnet, and Universe 1–4.
If you are using 4 ÉPIX™ Strip 2.0 products on a single output, the starting channel
should remain at 1.
In the order of connection, outward from the ÉPIX™ Drive 642, each ÉPIX™ Strip 2.0 will
automatically have the following Art-Net™ address: 1, 121, 241, 361.
The start channel on the lighting controller (or video/media server) should be
set to these start channels in order to have independent control of each
ÉPIX™ Strip 2.0.