3.3.5
Positioner board (OPTION)
Positioner board is assembled
on the main board.
You can switch between mA
and V using the small switch at
the base of the board according
to your needs.
3.3.6
Heating resistor
Each actuator includes a heating resistor.
As soon as the actuator is installed in the field, it is recommended
to supply the resistor to prevent condensation.
•
Immediately put the cover back in place after start-up while
ensuring its seal is clean. Never leave actuator electrical
components without their protection cover.
In case of water intrusion:
•
dry electrical components before putting back the cover.
•
check electrical insulation.
3.4 Closing the control compartment
To close the control compartment, see §3.2 and follow the
steps in the opposite order.
Make sure to re-plug the cover on the mainboard, otherwise control
panel (see §4.1) will not work.