Functions
The following tables show functions available from the network and the corresponding messages:
Settings
Settings functions are used to change the configuration of the product.
Command
Type
Set motor speed for rolling applications
Setting
Set Intermediate Positions (up to 16)
Controls
Control functions are used to change the status of the product.
Command
Type
Move to absolute position (UP/DOWN/IP)
Control
Move to relative position (Jog/Next IP)
Copyright © 2010 Somfy SAS. All rights reserved - V1 - 01/2011
All manuals and user guides at all-guides.com
Function
Set motor limits
Set motor rotation direction
Enable/Disable dry contact inputs
Recall factory settings
Function
Move in momentary mode
Stop movement
Feedback
Message
SET_MOTOR_LIMITS (11h)
SET_MOTOR_DIRECTION (12h)
SET_MOTOR_ROLLING_SPEED (13h)
SET_MOTOR_IP (15h)
SET_DCT_LOCK (17h)
SET_FACTORY_DEFAULT (1Fh)
Message
CTRL_MOVE (01h)
CTRL_STOP (02h)
CTRL_MOVETO (03h)
CTRL_MOVEOF (04h)
CTRL_WINK (05h)
In / Out
>> In
>> In
>> In
>> In
>> In
>> In
In / Out
>> In
>> In
>> In
>> In
>> In