AQUA-BASE
ARUBA Premium
Technical manual
Code
Description
Faults
A000-0
Electrical fault P04
A000-1
Electrical fault P40
A001-0
Electrical fault
A001-1
Low pressure fault (<0,3bar)
A001-2
Water shortage (<0,5bar at starting the unit)
A001-3
No pression at start-up (PSn06)
A002-0
Position fault (V10)
A004-0
Electrical fault
A004-1
Low pressure fault (<0,3bar)
A004-2
Water shortage (<0,5bar at starting the unit)
A004-3
Filters clogged
A004-4
No pression at start-up (PSn34)
A005-0
Electrical fault
A005-1
HP fault (>72bar)
A005-2
No pression at start-up (PSn43)
A006-0
Electrical fault (flowmeter)
A006-1
High flow fault
A007-0
Electrical fault
A007-1
Salinity fault
A009-0
Cleaning fault V48 closed
Alarms
A101-0
Replace prefilters
A102-0
Oil change needed
A102-1
Replace pump check valves
A103-0
Chemical cleaning needed
If you need assistance in resolving or identifying the source of the problem, ordering replacement parts, or
need operating advice, do not hesitate to contact your nearest
3.6.4
Bluetooth connectivity and smartphone application
The smartphone application is available in the apple app store and the
google play store. It enables a realtime connection to the watermaker with
detailed visualisation.
Name of the application: "Aqua-Base"
•
Potential problem source / Possible remedy
- Circuit breaker D04 has tripped
- Circuit breaker D40 has tripped
- Pressure sensor PSn06 unplugged
- Pressure sensor PSn06 needs to be replaced
- Seawater inlet valve (V01) is closed
- Hull valve is closed
- Flexible inlet hose is obstructed
- Sandfilter clogged; perform backwash/replace media.
- Verify the points mentioned for fault A001-2
- Verify the correct functioning op the feed pump (P04)
- The automatic sandfilter valve does not correspond with the
machine
- Pressure sensor PSn34 unplugged
- Pressure sensor PSn34 needs to be replaced
- Seawater inlet valve (V01) is closed
- Hull valve is closed
- Flexible inlet hose is obstructed
- Sandfilter clogged; perform backwash/replace media.
- Cartridge filters are clogged and need to be replaced.
- Verify the points mentioned for fault A001-2
- Verify the correct functioning op the feed pump (P04)
- Pressure sensor PSn43 unplugged
- Pressure sensor PSn43 needs to be replaced
- Reject valve closed
- Possible conflict with activated tank level sensor option.
- Verify the points mentioned for fault A001-2
- Verify the correct functioning op the HP pump (P40)
- By-pass valve V48 is open
- Fi61 unplugged
- Membrane(s) damaged. Replace membrane(s).
- Salinity probe Ce62 unplugged
- Salinity probe Ce62 needs to be replaced
- Salinity probe Ce62 needs to be cleaned
- Salinity probe Ce62 needs to be replaced
- Membrane(s) damaged
-V48 has not been opened for the cleaning cycle
- Replace the 20µ et 5µ cartridges
- Maintenance operations of the HP (P40) needed
- Membrane cleaning operation needed
AQUA-BASE
agent.
REV.H