AQUA-BASE
ARUBA Premium
Technical manual
Always use dubble hose clambs in order to have an extra failsafe, pressure resistant connection
between the hose and the fitting.
To assemble a pipe on its fitting, proceed as shown on the figure:
1 - Place the hose clamps, without tightening, then place the pipe
on the fitting,
2 - Slide the hose clamps to the fitting level and tighten them.
Ref.:
Caracteristics:
A1
A2
Ø25*33
5 bar Translucent
reinforced hose
A3
SLCE Ref.: 301189
A8
A4
Ø19*27
20bar
A5
BLACK PVC
A6
FOOD approval
A7
SLCE Ref.: 717303
Ø8*13
B1
20bar
BLACK PVC
B2
FOOD approval
SLCE Ref.: 717276
B3
Ø10*12
C1
RILSAN TUBE
SLCE Ref.: 719218
*The flushing subset is to be installed between the strainer (F02) and the feeding pump (P04) except when the sandfilter
option is also installed. In this case the flushing subset is to be installed between the sandfilter subset and the prefiltration
subset. (the A4 hose)
Supplemental hydraulic connections to be made on the MODULAR version:
D1
SLCE Ref.: 710098
D2
E1
Ø8*10
RILSAN TUBE
E2
SLCE Ref.: 719107
After the first time starting up the watermaker, thoroughly check each hydraulic connection for eventual
leaks.
•
Connection type:
Connects:
Seawater inlet (V0) (hull fitting and valve not supplied) to the intake valve (V01)
Seawater strainer (F02) to the flushing valve (V17) *
The flushing valve (V17) to the feeding pump (P04)
or
- Feeding pump (P04) to sandfilter inlet (if this option is installed) *
Hose clamps
Auxiliary tank (not supplied) to the intake valve (V01)
The feeding pump (P04) to the prefiltration (F30-F32)
Prefiltration (F30-F32) to the watermaker inlet (PWI)
Watermaker outlet (SWO) to the 3-way cleaning valve (V50)
3-way cleaning valve (V50) to the auxiliary tank
- Watermaker fresh water outlet (FWO) to the neutralite filter (if installed)
- Watermaker fresh water outlet (FWO) to 3-way sampling valve (if installed)
- Watermaker fresh water outlet (FWO) to on-board fresh water tank
3-way sampling valve to on-board fresh water tank
Hose clamps or
Quick fitting
3-way sampling valve to sampling recipient
On board pressurized fresh water supply to the auto flush subset (FWI)
(The water from the on-board water network cannot contain more than 0.4 mg/L of
chlorine)
HP pump subset to the Membrane pack subset
HP line connexions
Membrane pack subset to the regulating valve (V49) on the control-panel.
Membrane pack subset to the production valve subset
Quick fitting
Production valve subset to reject valve.
REV.H
P15/129