OPERATION AND MAINTENANCE MANUAL
TPD1456
Models 251A1 and 251A3 Sump Pumps are particularly recommended for contractors and
maintenance crews where lightweight, compactness, and low air consumption are prime
factors.
Ingersoll–Rand is not responsible for customer modification of pumps for applications on
which Ingersoll–Rand was not consulted.
READ THIS MANUAL BEFORE OPERATING PUMP.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PLACE THE INFORMATION
IN THIS MANUAL INTO THE HANDS OF THE OPERATOR.
FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY.
PLACING PUMPS IN SERVICE
Always operate, inspect and maintain this tool in
accordance with American National Standards
Institute Safety Code for Portable Air Tools
(ANSI B186.1).
For safety, top performance, and maximum
durability of parts, operate this pump at 90 psig
(6.2 bar/620 kPa) maximum air pressure at the inlet
with 1" (25 mm) inside diameter air supply hose.
Always turn off the air supply and disconnect the
air supply hose before installing, removing or
adjusting any accessory on this pump, or before
performing any maintenance on this pump.
Do not use damaged, frayed or deteriorated air
hoses and fittings.
Be sure all hoses and fittings are the correct size
and are tightly secured. See Dwg. TPD905–1 for a
typical piping arrangement.
The use of other than genuine Ingersoll–Rand replacement parts may result in safety hazards, decreased pump
performance, and increased maintenance, and may invalidate all warranties.
Repairs should be made only by authorized trained personnel. Consult your nearest Ingersoll–Rand Authorized
Servicenter.
Refer All Communications to the Nearest
Ingersoll–Rand Office or Distributor.
Ingersoll–Rand Company 1996
Printed in U.S.A.
All manuals and user guides at all-guides.com
251A1 AND 251A3 SUMP PUMPS
IMPORTANT SAFETY INFORMATION ENCLOSED.
03524360
Always use clean, dry air at 90 psig maximum air
pressure. Dust, corrosive fumes and/or excessive
moisture can ruin the motor of an air pump.
Do not lubricate pumps with flammable or volatile
liquids such as kerosene, diesel or jet fuel.
Do not remove any labels. Replace any damaged
label.
USING THE PUMP
Always wear eye protection when operating or
performing maintenance on this pump.
Always wear hearing protection when operating
this pump.
Use accessories recommended by Ingersoll–Rand.
Do not start or operate this pump unless it is
submerged.
This pump is not designed for working in explosive
atmospheres.
This pump is not insulated against electric shock.
F
Form P5931
Edition 12
E
March, 1996
P

Publicité

loading

Sommaire des Matières pour Ingersoll Rand PROFESSIONAL TOOLS 251A1

  • Page 1 All manuals and user guides at all-guides.com 03524360 Form P5931 Edition 12 March, 1996 OPERATION AND MAINTENANCE MANUAL 251A1 AND 251A3 SUMP PUMPS TPD1456 Models 251A1 and 251A3 Sump Pumps are particularly recommended for contractors and maintenance crews where lightweight, compactness, and low air consumption are prime factors.
  • Page 2 All manuals and user guides at all-guides.com WARNING LABEL IDENTIFICATION FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY. WARNING WARNING WARNING Always turn off the air sup- Always wear eye protection Always wear hearing ply and disconnect the air when operating or perform- protection when operating supply hose before instal-...
  • Page 3 All manuals and user guides at all-guides.com PLACING PUMP IN SERVICE LUBRICATION OPERATION Always use an Exhaust Hose and be certain the free end of the Hose is kept well above the surface of the liquid. Ingersoll–Rand No. 50 Ingersoll–Rand No. 80 Do not allow the pump to operate at free speed (not Water Pump Grease submerged) for long periods of time.
  • Page 4 All manuals and user guides at all-guides.com MANUEL D’EXPLOITATION ET D’ENTRETIEN POUR MODÈLES 251A1 ET 251A3 NOTE TPD1456 Les pompes d’épuisement Modèles 251A1 et 251A3 sont destinées aux entrepreneurs et aux équipes d’entretien pour lesquels la légèreté, les faibles dimensions et la faible consommation d’air sont des facteurs principaux.
  • Page 5 All manuals and user guides at all-guides.com SIGNIFICATION DES ÉTIQUETTES D’AVERTISSEMENT ATTENTION LE NON RESPECT DES AVERTISSEMENTS SUIVANTS PEUT CAUSER DES BLESSURES ATTENTION ATTENTION ATTENTION Couper toujours l’alimentation Porter toujours une Porter toujours des lunettes d’air comprimé et débrancher le protection acoustique de protection pendant flexible d’alimentation avant...
  • Page 6 All manuals and user guides at all-guides.com MISE EN SERVICE DES POMPES LUBRIFICATION FONCTIONNEMENT Utiliser toujours un flexible d’échappement et s’assurer que son extrémité libre est maintenue au–dessus de la surface Ingersoll–Rand No. 50 Ingersoll–Rand No. 80 du liquide. La graisse de pompe à eau Ne pas laisser tourner la pompe à...
  • Page 7 All manuals and user guides at all-guides.com MANUAL DE FUNCIONAMENTO Y MANTENIMIENTO MODELOS 251A1 Y 251A3 NOTA TPD1456 Las bombas centrífugas modelos 251A1 y 251A3 se recomiendan particularmente para contratistas y plantillas de mantenimiento para los que los factores más importantes sean peso ligero, compacidad y baja consumición de aire.
  • Page 8 All manuals and user guides at all-guides.com ETIQUETAS DE AVISO AVISO EL HACER CASO OMISO DE LOS AVISOS SIGUIENTES PODRÍA OCASIONAR LESIONES. ADVERTENCIA ADVERTENCIA ADVERTENCIA Cortar siempre el suministro Usar siempre protección ocular Usar siempre protección de aire y desconectar la man- al manejar o realizar opera- para los oídos al manejar guera de suministro de aire...
  • Page 9 All manuals and user guides at all-guides.com PARA PONER LA BOMBA EN SERVICIO LUBRICACIÓN FUNCIONAMIENTO Utilice siempre siempre una manguera de escape y asegúrese de que el extremo abierto de la manguera se Ingersoll–Rand Nº. 50 Ingersoll–Rand Nº. 80 mantenga por encima de la superficie del líquido. Grasa para bomba de agua No permita que la bomba funcione a velocidad en vacío No use nunca grasa semisólida ordinaria, puesto que se...
  • Page 10 All manuals and user guides at all-guides.com MANUAL DE FUNCIONAMENTO E MANUENÇÃO MODELOS 251A1 E 251A3 TPD1456 AVISO As Bombas Centrífugas Modelos 251A1 e 251A3 são particularmente recomendadas para empresas contratadas e grupos de manutenção onde pesos leves, a compacidade e o baixo consumo de ar são factores primários.
  • Page 11 All manuals and user guides at all-guides.com IDENTIFICAÇÃO DO RÓTULO DE ADVERTÊNCIA ADVERTÊNCIA O NÃO CUMPRIMENTO DAS SEGUINTES ADVERTÊNCIAS PODE RESULTAR EM FERIMENTOS. ADVERTÊNCIA ADVERTÊNCIA ADVERTÊNCIA Use sempre protecção contra o Desligue sempre a alimentação Use sempre óculos de ruído ao operar esta ferramenta. de ar e desconecte a protecção quando estiver mangueira de alimentação de...
  • Page 12 All manuals and user guides at all-guides.com COLOCANDO A FERRAMENTA EM FUNCIONAMENTO LUBRIFICAÇÃO OPERAÇÃO Use sempre uma Mangueira de Exaustão e esteja certo de que a extremidade livre da Mangueira é mantida bem acima da superfície do líquido. Ingersoll–Rand No. 50 Ingersoll–Rand No.
  • Page 13 All manuals and user guides at all-guides.com (Dwg. TPA271–1)
  • Page 14 All manuals and user guides at all-guides.com PART NUMBER FOR ORDERING PART NUMBER FOR ORDERING Motor Housing Backhead ....... . P250–102 2 1/2”...
  • Page 15 All manuals and user guides at all-guides.com PART NUMBER FOR ORDERING PART NUMBER FOR ORDERING Arbor Bearing Spring ..... . . 9BM–278 1”...
  • Page 16 All manuals and user guides at all-guides.com MAINTENANCE SECTION 5. While grasping the Governor Assembly (17) in one hand, gently tap on the impeller end of the Arbor (47) with a plastic hammer and withdraw the assembled Always wear eye protection when operating or motor and Arbor.
  • Page 17 All manuals and user guides at all-guides.com MAINTENANCE SECTION 6. Place the Rear End Plate (14) and Rear Arbor The correct governed free speeds for these pumps are: Bearing (26) on the Rotor. Model Speed, rpm In the following step, the Govenor Assembly (17) 251A1 5 200 has a left–hand thread;...
  • Page 18 All manuals and user guides at all-guides.com MAINTENANCE SECTION TROUBLESHOOTING GUIDE Trouble Probable Cause Solution Low power or low free speed Dirty Air Strainer Screen Using a clean, suitable, cleaning solution in a well– ventilated area, clean the Air Strainer Screen. Allow to air dry.
  • Page 19 All manuals and user guides at all-guides.com NOTES...

Ce manuel est également adapté pour:

Professional tools 251a3