3.4
Contact assignment
PIN
1
Input contact I
Open: sensor armed
At ground (Pin 5): Sensor disarmed
2
Input contact II
Open: Parameter set I active
At ground (Pin 5):
Parameter set II active
3
Output contact I
Internally switched to ground: Object detected
Open: No object detected
(constant signal, impulse or periodic impulse)
4
Output contact II
Internally switched to ground:
Video signal malfunction
Open: Video signal OK
5
Ground
6
Relay I
6/7 closed: Malfunction
7
Relay I (Middle contact)
8
Relay I
8/7 closed: No malfunction
Relay II
9
9/10 closed: No alarm
10
Relay II (Middle contact)
Relay II
11
11/10 closed: Alarm
12
Remote control Rotary switch:
Backwards in alarm archive (–) when turned left
13
Remote control Rotary switch:
– Switchover: Live image/alarm archive
– active >2 secs. = alarm acknowledgement
14
Remote control Rotary switch:
Forwards in alarm archive (–) when turned right
15
Remote control Rotary switch: Ground
Input contacts
Remote control
Functions continued
Function
+5V
1/2
12/13/14
5/15
– 9 –
Electrical specification
Internal pull-up
Internal pull-up
Open collector,
max. 100mA, 12V
Externally switchable
Open collector,
max. 100mA, 12V
Externally switchable
Max. 30V, max. 1A
Max. 30V, max. 1A
Max. 30V, max. 1A
Max. 30V, max. 1A
Max. 30V, max. 1A
Max. 30V, max. 1A
Internal pull-up
Internal pull-up
Internal pull-up
Output contacts
3/4
5/15
A1 February 03/Trb