All manuals and user guides at all-guides.com
2
Mounting
2.1
General mounting notes
– Use only cable specified by the manufacturer. Protection against
malfunction cannot otherwise be guaranteed.
– To guarantee operational safety, only those power supplies specified by the
manufacturer may be used. (individual devices: power supply VMD–PS, for
19" installation, the power supply is integrated in the VMD–RA frame).
– For questions regarding setup, environmental conditions and safety of
individual components, manufacturer documentation must be consulted.
– For installation, this instruction manual and the specific connection
instructions are to be followed.
– This description does not contain information about installation and setup of
the camera, monitor and recorder.
2.1.1
Mounting Variants
Housing vertical
Four feet must be fitted to the unit base plate. The connecting cable must have
sufficient strain relief.
Housing can be stacked upright.
Warning!
Maximum of four units can be stacked upright on top of each other.
If housings are stacked on top of each other, the feet on the underside of the
housing must be fitted. There are no locking springs for the bottom unit. For all
other units to be stacked, the locking springs must be pushed into the feet and
pressed into the locating slits on the bottom unit. Ensure sufficient strain relief.
3. Press down with blunt object
Feet
– 5 –
English
Unit feet
1. Press in
2. Press in
Locking
spring
A1 February 03/Trb