Indicator lamp
The indicator lamps display the operating
states (green) and interruptions (red).
Reset:
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Operating status display
Continuous green:
The appliance is now ready for opera-
–
tion.
1x blinking green:
Operational readiness has expired after
–
30 minutes.
The appliance has switched off after 30
–
minutes of continuous operation (safety
if the high pressure hose bursts).
Fault indication
Continuous red light:
Electrical problems in appliance
–
Pull out the mains plug.
Call Customer Service.
1x blinking red:
High pressure side is leaky
–
Check high pressure hose, hose con-
nections and hand spray gun for leaks.
2x blinking red:
Engine overload/overheat
–
Set the appliance switch to "0".
Allow device to cool down.
Set the appliance switch to "I".
Water pressure is too low
–
Ensure adequate water line pressure.
3x blinking red:
Fault in the voltage supply
–
Check main connections and mains
fuse.
4x blinking red:
Power consumption is too high
–
Call Customer Service.
22
All manuals and user guides at all-guides.com
–
Check whether the voltage indicated on
Check the mains connection cable for
–
Operational readiness period has ex-
–
Check water inlet pressure, minimum
–
Switch off appliance and let it cool
–
Check nozzle for correct size (see tech-
–
Clean/ replace nozzle.
–
Clean filter at the water connection.
–
Appliance ventilation:
–
Check all supply lines to the pump for
– 8
EN
Appliance is not running
No power
the type plate corresponds to the volt-
age of the socket.
damages.
Indicator lamp is blinking green
pired. Switch on/off the appliance
again.
The water shortage fuse (option) was
triggered due to low water inlet pres-
sure.
The indicator lamp "lack of water" will il-
luminate.
value see "Specifications".
Turn the device switch to "0" and turn
on again to restart the system.
Motor overloaded/ over-heated or elec-
trical circuit breaker or winding protec-
tion switch has got released.
down. Remove the cause of the prob-
lem. Turn on the appliance again.
Device is not building up pressure
Wrong nozzle
nical specifications).
Flushed the nozzle.
Filter is dirty.
Unscrew the filter casing, remove the
filter, clean it and replace it.
Air within the system
Unscrew the nozzle. Switch on the ap-
pliance and let it run until the water ex-
iting from the spray pipe is bubble-free.
Switch off the appliance and fit the noz-
zle again.
Pipe inlets to pump are leaky or blocked
leaks or blockages.