INSTALLATION SUPER 4000
CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.: Gate features must be uniformed with the standards and laws in force. The door/gate
can be automated only if it is in a good condition and its conditions comply with the
EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the opposite case it is
necessary to take the appropriate steps, in accordance with EN 12453 point 6.5.1 (for
instance; by preventing the operation of the motor when the pedestrian opening is opened,
by installing a safety microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the operators, there must
be, on both ends of the installation, a fixed mechanical stopper which stop the gate in the
unlikely event of ill functioning of limit swithces on the operators. For this reason the fixed
mechanical stopper must be of an adeguate size to withstand the static and kinetic forces
generated by the gate (12) (Fig.2).The guide must be provided with two mechanical stops
at its ends (12) (Fig. 2).
- Gate columns shall have anti-derailment guides on their top (Fig. 3), to avoid the
unintentional gate release.
N.B.: Eliminate those mechanical stops of the kind described by figure 3.
No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough.
Parts to install according to EN 12453 standard
COMMAND TYPE
(out of public area*)
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
MOTOR AND RACK INSTALLATION
The base of the ratiomotor is equipped with 4 anchors so that it can be
cemented to the ground.
The rack must be fixed at a certain height with respect to the motor base.
This height can be varied thanks to the slots on the rack.
The rack must not be welded, but simply fixed to the gate with threaded screws.
The height needs to be adjusted so that the gate does not rest on the reduction unit
traction gear (Fig. 4, 5).
Holes with a diameter of 7 mm should be made to fix the rack into the gate, and they
should be threaded using a M8 type screw tap.
The pinion must have a clearance of 1 to 2 mm with respect to the rack.
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E
28
Misure in mm
2
3
4
5