COMPUTER
The supplied computer allows the most convenient training.
Every value relevant to training is displayed in a corresponding
window.
From the beginning of the training session, the required time, the
current speed, the approximate calorie consumption, the travel-
led distance ad the current pulse rate are displayed. All values
are counted from zero upwards. If you wish to see one value
displayed constantly during training, select this with the [F] - key.
If you wish to see these values in constant alternation, select the
„SCAN" function. The display then changes from one function to
the next at intervals of approx. 6 seconds.
The computer is switched on by briey pressing the [F] -
key or simply by beginning training. The computer begins to
register and display all values. To stop the computer, just stop
training. The computer stops all measurements and retains the last
attained values. The last values achieved in the TIME, CALORIES
and KM functions are saved for 4 minutes and when you resume
training, you can continue training from these values or set all
unctions to zero using the [L] - key. The computer switches o
automatically approx. 4 minutes after the end of the training.
DISPLAYS
[SPEED] - Km/h display:
The current speed is displayed in kilometres per hour. It is not
possible to specify a particular value using the [E] - key. The
values last attained by this function are not stored. (Limit of the
display: 999.9 km/h.)
[TIME] - Time display:
The currently required time is displayed in minutes and
seconds. It is possible to specify a particular value using the [E] -
key. I a particular time has been specied, the remaining time is
displayed. When the specied value is attained, this is indicated
by an acoustic signal. The values last attained by this function
are stored. (Limit of the display: 99 minutes.)
[DIST] - Km dispaly:
The current status of the travelled distance is displayed. It is
possible to specify a particular value using the [E] - key. If a par-
ticular distance has been specied, the remaining distance is
displayed. When the specied value is attained, this is indicated
by an acoustic signal. The values last attained by this function
are stored. (Limit of the display: 999,9 km.)
[CAL] - Calories display:
The current status of the consumed calories is displayed. It is
possible to specify a particular value using the [E] - key. If a par-
ticular consumption has been specied, the remaining number o
calories to be consumed is displayed. When the specied value
is attained, this is indicated by anacoustic signal. The values last
attained by this function are stored. (Limit of the display: 999,0
calories.)
[PULS] - Pulse display:
The current pulse rate is displayed in beats per minute. It is
possible tospecify a particular value using the [E] - key.
The values last attained by this function are not stored. (Limit of
both displays:40 – 240 pulse beats per minute.)
Attention!
For pulse measurement, the two contact surfaces of the
pulse measuring handle unit must be gripped simultaneously.
The contact surfaces should be located centrally in the palms of
the hands.
[SCAN] - Function:
If this function is selected, the current values of all functions are
displayed successively in a constant sequence approx. every 5
seconds.
[STOP] - Display:
Display of Stopmode. Presets can be set.
KEYS
[F] - Key (Funktion):
Pressing this key once briey makes it possible to change rom
one function to another, i.e. the respective functions can be se-
lected for which entries can be made using the [E] - key. The cur-
rently selected function is indicatedin the window.
[E] - Key (Enter):
By pressing this key once, it is possible to specify values step
by step in the respective functions. For this, the desired function
must rstly be selected using the [F] - key. Holding the key pres-
sed activates aster running. When training begins, the specied
values are then counted down to zero.
[L] - Key (Delete):
When this key is pressed briey, the values chosen with the [F]
- key are reset to zero. If the key is held longer (approx. 3 se-
conds), all last attained values are deleted.
REPLACING THE BATTERIES
1. Open the battery compartment cover and then remove the
used Batteries.(If the batteries should leak remove them under
increased considering that the battery acid is not into contact with
skin come and clean the battery compartment thoroughly.)
2.
Insert
the
new
the
correct
order
polarity in the battery compartment and close the batterycover so
that it clicks into place.
3. If the computer does not pick up immediately, the function
should batteries are removed for 10 seconds and re-inserted.
4. The empty batteries properly in accordance with the disposal
regula tions disposed of and do not give residual waste.
Battery compartment
AAA batteries
21
batteries
(type
(AAA)
and
taking
into
account
GB
1.5
V
in
the