Shut down procedure

1. Switch off the device at the mains switch (see
chapter "Operating elements").
2. Do not touch the mains plug with wet or damp
hands.
3. Remove the mains plug from the mains socket.
4. Empty the condensation tank and wipe it dry with
a clean cloth. Check for dripping condensation.
5. Clean the device, and especially the air filter,
according to chapter "Maintenance".
6. Store the device according to chapter "Storage".

Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist
company for cooling and air-conditioning or by
Trotec.
The device runs but forms no condensation:
• Check the condensation tank is positioned
correctly. Check the fill level of the condensation
tank and empty it if necessary. The condensation
tank indicator light must not light up.
• Check the float in the condensation tank for
damages. If necessary, clean the float and
condensation tank. The float must be able to move
freely.
• Check the room temperature. The working range
of the device is between 5 °C and 35 °C.
• Ensure that the relative humidity complies with the
technical data (min. 40 %).
EN
• Check the set operation mode. The humidity in the
room must be above the selected range. If
necessary, turn the rotary switch (7) to the right to
"MAX" (09).
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
• From the outside, check the condenser is not dirty
(see chapter "Maintenance"). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by Trotec.
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty.
Remove external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the
condenser for external dirt (see chapter
"Maintenance"). If the inside of the device is dirty,
have it cleaned by a specialist company for cooling
and air-conditioning or by Trotec.
Does your device still not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to Trotec for repairs.