Shut Down Procedure; Errors And Faults - Trotec MD 01-10 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30

Shut down procedure

1. Turn the rotary switch (8) anticlockwise as far as
possible (see "Operating elements" chapter).
2. Do not touch the mains plug with wet or damp
hands.
3. Remove the mains plug from the mains socket.
4. Empty the condensation tank and wipe it dry with
a clean cloth. Check for dripping condensation.
5. Clean the device, and especially the air filter,
according to chapter "Maintenance".
6. Store the device according to chapter "Storage".

Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist
company for cooling and air-conditioning or by
®
TROTEC
.
The device runs but forms no condensation:
• Check the condensation tank is positioned
correctly. Check the fill level of the condensation
tank and empty it if necessary. The condensation
tank indicator light must not light up.
• Check the float in the condensation tank for
damages. If necessary, clean the float and
condensation tank. The float must be able to move
freely.
B - 9
• Check the room temperature. The working range
of the device is between 5 °C and 35 °C.
• Ensure that the relative humidity complies with the
technical data (min. 40 %).
• Check that the selected humidity is realistic. The
humidity in the room must be above the selected
range. If necessary, turn the rotary switch (8)
clockwise.
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
• From the outside, check the condenser is not dirty
(see chapter "Maintenance").
If your condenser is dirty, have it cleaned by a
specialist
air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty.
Remove external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator, the
condenser and the condensation pump for
external dirt (see "Maintenance" chapter). If the
inside of the device is dirty, have it cleaned by a
specialist
conditioning or by TROTEC
Does your device still not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
Operating Manual – Dehumidifier MD 01-10
company
for
cooling
®
.
company
for
cooling
®
.
®
for repairs.
and
and
air-
EN