Shut down procedure

1. Switch off the device at the mains switch
(see chapter "Operating elements").
2. Do not touch the mains plug with wet or damp
hands.
3. Remove the mains plug from the mains socket.
4. Empty the condensation tank and wipe it dry with
a clean cloth. Check for dripping condensation.
5. Clean the device, and especially the air filter,
according to chapter "Maintenance".
6. Store the device according to chapter "Storage".

Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist compa-
ny for cooling and air-conditioning or by
®
TROTEC
.
The device runs but forms no condensation:
• Check the condensation tank is positioned correct-
ly. Check the fill level of the condensation tank and
empty it if necessary. The condensation tank
indicator light must not light up.
• Check the float in the condensation tank for
damages. If necessary, clean the float and
condensation tank. The float must be able to move
freely.
B - 9
• Check the room temperature. The working range
of the device is between 5 °C and 35 °C.
• Ensure that the relative humidity complies with the
technical data (min. 49 %).
• Check the preset humidity is as you want. The
humidity in the room must be above the selected
range. If necessary, turn the rotary switch (15)
clockwise towards "MIN".
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
• From the outside, check the condenser is not dirty
(see chapter "Maintenance"). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty.
Remove external dirt.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the
condenser for external dirt (see chapter "Main-
tenance"). If the inside of the device is dirty, have
it cleaned by a specialist company for cooling and
air-conditioning or by TROTEC
Your device still does not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
Operating manual – Dehumidifier TTK 75 S
®
.
®
.
®
for repairs.