Fault
The device does not cool (plug is
inserted). Temperature indicator LEDs
for 11 °C (51 °F) and 14 °C (57 °F) light
up permanently.
The interior LED lamp stays on perma-
nently even when the wine cooling
drawer is closed.
The device does not cool sufficiently.
Temperature indicator LEDs glow.
The upper temperature indicator LED
flashes repeatedly for 1 time.
The upper temperature indicator LED
flashes repeatedly for 3 times.
The upper temperature indicator LED
flashes repeatedly for 4 times.
The upper temperature indicator LED
flashes repeatedly for 5 times.
The upper temperature indicator LED
flashes repeatedly for 6 times.
Cleaning and maintenance
!
WARNING! Fire hazard
• The refrigerant is highly flammable. Do
not open or damage the refrigerant
circuit.
• The insulation of the device contains
an insulating gas (see data plate).
Do not damage the insulation.
A
NOTICE! Damage hazard
• Do not use abrasive cleaning agents or
hard objects during cleaning.
• Never use hard or sharp tools to
remove ice or to free frozen objects.
• Do not use any mechanical tools or any
other tools to speed up the defrosting
process.
18
Possible cause
The demo mode is activated.
The presentation mode is acti-
vated.
The cooling element is defective. ➤ Contact authorized service agent
The ventilation is insufficient.
The temperature sensor is defec-
tive.
The inner fan is defective.
The outer fan is defective.
The drawer is opened for too
long.
The drawer is not closed prop-
erly.
The compressor is defective.
➤Clean the device interior and exterior regularly
with a damp cloth and as soon as it becomes
dirty.
➤Wipe the wine cooling drawer dry with a cloth
after cleaning.
➤Ensure that the air inlet and outlet vents on the
device are free from any dust and dirt, so that
heat can be released and the device is not dam-
aged.
➤Check the condensate drain regularly.
Clean the condensate drain when necessary. If it
is blocked, the condensate collects on the bot-
tom of the wine cooling drawer.
4445103702
Suggested remedy
➤ Switch off the demo mode (fig. h,
page 10).
➤ Switch off the presentation mode
(fig. g, page 10).
for repair.
➤ Remove any obstruction or soiling
from the inlet and outlet vents.
➤ Contact authorized service agent
for repair.
➤ Contact authorized service agent
for repair.
➤ Contact authorized service agent
for repair.
➤ Close the drawer.
➤ Close the drawer properly.
➤ Contact authorized service agent
for repair.