3 front screws
(4 rear screws required
but not shown)
attaching the
backguard
attaching the island
trim
center hole
not used
9
u Attach the backguard or island trim
as required for your installation.
Attachment screws are in the literature
package.
1
0
w Slide range completely back so
anti-tip bracket is over rear brace of
range.
use pipe-joint
compound
regulator
flexible
/
cgnmecto
\ 4/2 tan
4/2" to 3/4" gas
union adapter
pipe
a 1/2" male pipe thread is needed for connection
to pressure regulator female pipe threads
manual gas
shutoff valve
1 1
a Make gas connection. Assemble
flexible connector from gas supply pipe to
pressure regulator located in the middle
front of the range. Apply pipe-joint
compound made for use with L.P. gas to
the smaller thread ends of the flexible
connector adapters. Attach one adapter
to the pressure regulator elbow and the
other adapter to the gas shutoff valve.
Tighten both adapters.
12
w Open manual shutoff valve in
gas supply line. Wait a few minutes for
gas to move through the line.
13
u Use a brush and liquid
detergent to test all gas connections.
Bubbles around connections will indicate
a leak. If a leak appears, shut off gas
valve controls and tighten connections.
Then check connections again. Clean all
detergent from range.
14
a Remove cooktop burner caps,
grates, and simmer plate from the parts
package. Align the indentation in the
burner cap with the pins on the burner
base. Burner caps should be level when
properly positioned.
1 5
w Turn on power supply. "PF"
should appear in the clock display. (Refer
to your Use and Care Guide for
instructions on using the electronic
control.)
1 6 a Check
operation of cooktop
burners. Push in and turn
each control knob to the
"LITE" position. The
flame should light within
4 seconds. The first time a burner is
lighted it may take longer than 4 seconds
to light because of air in the gas line.
1
t
w If burners do not light properly,
turn cooktop control knob to the "OFF"
position. Check that power supply conduit
is properly wired and that circuit breaker
or fuse has not blown. Check that gas
shutoff valves are set to the "OPEN"
position. Repeat step 16. If a burner still
does not light, contact your KitchenAid
dealer or designated service company.
1
8
a Adjust height of top burner
flames. The cooktop LOW burner flame
should be a steady blue flame
approximately 1/4" (6 mm) high. It can be
adjusted using the adjustment screw in
the center of the valve stem. The valve
stem is located directly underneath the
control knob. If the LOW flame needs to
be adjusted:
a. Remove the control knob.
b. Hold control
=
knob stem
control knob
with a pair of
stem
pliers. Use a
small flat-head
screwdriver to
turn screw
located in the
center of control knob stem until
flame is the proper size.
c. Replace conirol knob.
d. Test the flame by turning the control
from "LO" to "HI', checking flame at
each setting.
Gas conversions
Gas conversions (from Natural gas to L.P.
gas or from L.P. gas to Natural gas) must
be done by a qualified installer.
L.P. gas conversion:
No attempt shall be made to convert the
range from the gas specified on the
model/serial rating plate for use with a
different gas without consulting the
servicing gas supplier. An L.P. Gas
Conversion Kit is included in your
literature package.