Télécharger Imprimer la page

Harman Mark Levinson 526 Manuel Du Propriétaire page 18

Masquer les pouces Voir aussi pour Mark Levinson 526:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
SETUP MENU
VOLUME CONTROL
SETUP MENU
Input Setup
VOLUME CONTROL
ENTER
Volume Control
Power Management
Volume Max
Display
Volume Mute
Advanced
Volume Turn On
Output Setup
SETUP
Volume Taper
Volume Control settings let you customize the performance of the
preamp's Volume and Mute functions.
Max Vol: this setting sets the maximum line output volume level in
0.1dB increments between 40.0dB and 80.0dB. The factory default
maximum volume is 80.0dB.
Mute: this setting lets you set the amount of line output level
attenuation that occurs when the Mute button is engaged, in 0.1dB
increments between –10dB and –80.0dB. The factory default mute
attenuation is –40dB.
Turn On: this setting lets you set a line output volume level to which
your preamp will default every time you turn it on.
o 10.0dB – 60.0dB: choose a turn-on volume level in 0.1dB
increments between 10.0db and 60.0db. The factory
default setting is 10.0dB.
o Last: the volume level setting from the previous time the
unit was powered down is retained.
CAUTION: setting the Turn-On parameter to Last can result in
louder-than-expected power-up volume if the preamp was set to a
high volume level setting when last powered down.
Taper: this setting lets you choose the desired taper for the volume
control, from the following options:
Mode 1 : the faster you rotate the volume knob the more quickly the
volume will change. Rotating the knob slowly slows the rate the
volume changes, allowing you to make very precise adjustments
in the listening level. This is the factory default setting.
Mode 2 : Similar to Mode 1, with a "faster" response curve, with
more gain change for a similar range of knob travel.
Mode 3 : When increasing the volume the volume changes quickly
through the low volume range, and then decelerates in the higher
range, for precision adjustments. When decreasing the volume the
control works in the opposite fashion, changing quickly through
the high volume range and decelerating in the lower range.
16
N
526 / N
523 DUAL-MONAURAL PREAMPLIFIER
0
0
All manuals and user guides at all-guides.com
POWER MANAGEMENT AND DISPLAY
Input Setup
Volume Control
Max=80.0 dB (default)
Power Management
Mute=-40.0 dB (default)
Display
Turn On=10.0 dB (default)
Advanced
Taper=Mode 1 (default)
Output Setup
The Power Management and Display parameters let you
customize power-related functions.
Standby: this setting lets you set the Standby mode to one of the
following options:
Auto Off: this setting lets you engage or disengage the Auto Off
function, which puts your preamp into the Standby mode after
20 minutes of inactivity (no audio signal, and no control input).
Display: this menu gives you access to the following display
parameters:
/
OWNER'S MANUAL
SETUP MENU
POWER MANAGEMENT
ENTER
Standby
SETUP
Auto Off
Green : this mode removes power from almost all of the
circuits, allowing the unit to be activated only via an IR control
signal, a 5V – 12V trigger voltage or a press of the Standby
button. This mode provides maximum power conservation
and is the factory-default Standby mode.
Power Save : this mode removes power from the audio
circuits, but keeps the control circuitry powered and ready
to receive commands from either the front-panel controls
or the remote control. This mode provides moderate power
conservation.
Normal : this mode shuts off the display and mutes audio
outputs, but keeps all of the control and audio circuits
powered. This mode provides the least amount of power
conservation but allows the audio circuits to remain warmed
up to deliver optimal performance at all times.
Intensity : lets you set the brightness of your preamp's display
to High, Med, Low, or Off (which turns the display off entirely
until a control is operated). The factory default setting is High.
Timer (only applies when the display intensity is set to Off):
lets you choose how long the display remains lit after the
last time a control is operated. Choose from 10 seconds,
4 seconds, or 2 seconds. The factory default setting is 10
seconds.
Standby=Green (default)
Auto Off=On (default)

Publicité

loading

Ce manuel est également adapté pour:

Mark levinson 523