Télécharger Imprimer la page

Güde HPC 150 M Mode D'emploi page 57

Masquer les pouces Voir aussi pour HPC 150 M:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
Requirements on the Operator
The Operator shall carefully read Operation
Manual before using the apparatus.
Qualification
No special qualification is needed for the work,
just detailed training provided by the specialist.
Minimum Age
The apparatus may operate only persons at the
age of 16 years and more. An exception makes
the case is a special training for acquiring the skill
under supervision of a lecturer.
Training
Only corresponding instruction is needed for the
use of the apparatus. No special training is
necessary.
Technical data
Engine:
4-Stroke-OHV
Engine Power:
1,8 kW (2,4 PS)
Stroke Volume:
81 cm³
Engine Revolutions: 3600 min-1
Maximum Pressure:
1450 bar
Working Pressure:
110 bar
Water Output:
7l/min
Tank Volume:
1,6 l
Oil Volume:
0,37 l
Weight:
18 kg
Storing
Should the engine be not used for longer period
of time or should it be stored for at least one
month, following working steps shall be
observed.
Discharge all petrol from the tank and from the
choke.
Remove spark plug.
Put about 1 tablespoonfull of clean
engine oil into the cylinder for spark plug
insert.
At switched off engine pull several times
carefully the starting cord. Then insert
the ignition plug again and pull out the
starting cord until the piston is completely
up (compression point OT). Stop pulling
as soon as you feel perceptible
resistance.
Store the apparatus in a well ventilated, dry place
under protective cover so that no dust and dirty
may be deposited on it.
Measures for Storing for Winter or for a
longer Period of Time
If the apparatus is not used for at least 3 months
or if frosts are expected in winter months, the
pump shall be properly protected against damage
All manuals and user guides at all-guides.com
57
caused by frost or against freezing. Prepare
proper solution for protection in winter months
according to the instruction on the protective
means. Pour the solution carefully into the inlet of
the apparatus. After the solution dripped away at
the outlet, close it with cork or another suitable
plug or closing device. Place into the inlet so
much non-freezing liquid till the pump is full. Then
close the inlet with cork or another suitable plug.
Before using the apparatus after treatment with
protective non-freezing liquid all liquid shall be
discharged from the pump, hose and water piping
leading to the jet. After first restarting the
apparatus again a bit of liquid may pour out from
the pump. This pouring will stop shortly.
Installation
Remove all packing material from the apparatus.
Check the apparatus, all parts and accessories
and make sure that no part is missing and that no
damage occurred during the transportation.
Pump Plug (Fig. 5)
The apparatus is furnished with the plug
preventing
leakage
transportation. Remove the transport plug and
replace it with the plug with bleeding function that
is included in the delivery. The pump of the
apparatus has closed oil circulation that needs no
maintenance. (Refuelling or exchange of oil is not
necessary).
Before Putting into Operation
Observe the rules of your water company.
According to the EN 61 770 standard, the
appliance must not be immediately connected to
public drinking water supply. However, short-term
connection is according to DVGW (German
Association of Gas and Water Branch) accepted
if there is a backflow barrier with air intake inbuilt
in the supply line. Also mediated connection to
public drinking water supply through free output
according to EN 61 770 is allowed; e.g. by
inserting a container with a float valve. Immediate
connection to the line network not designed for
distribution of drinking water is admissible.
Following operations shall be performed before
putting the apparatus into operation:
pour the engine oil into gearbox
pour the petrol into the tank
connect the high-pressure hose to the
spray gun and to the pump
connect the pump to the water main
connect the jet to the spray gun
Important Warning: The engine and the pump
of your apparatus needs some period of time
to run in. Therefore the apparatus will operate
with full output after a few hours of operation.
of
the
oil
during

Publicité

loading

Ce manuel est également adapté pour:

86020