18
Changing the tool (figure 6).
Always secure the power tool
WARNING
with the supplied safety
strap. In case of a power failure or when the
mains plug is pulled, the magnetic holding
power is not maintained.
Switch the machine off and
WARNING
pull the power plug before
mounting or replacing application tools and
accessories (not overhead!). This preventive
safety measure rules out the danger of inju-
ries through accidental starting of the power
tool.
Swing out the chip guard to the side.
Loosen both screws of the tool holder using
the hex key.
Insert the pilot pin into the cutter.
Insert the cutter with the pilot pin into the
tool holder.
Tighten both screws of the tool holder onto
the flats on the cutting tool using the hex
key.
Fig. 6