Opening the backwater flap in the manual mode
Only possible if the backwater flap has been closed in the manual mode and there is no backwater (backwater
flap LED <22> is on).
•
Press the backwater flap key <25>, the backwater flap is moved from the CLOSED to the OPEN position.
The backwater flap LED <22> flashes during the change of position. The backwater flap is open when the
backwater flap LED <22> goes out and the display shows "Flap open".
5.6
Operating menu
The number <24> of the respective menu level is shown as a
figure in the top line on the display.
Opening the menu
•
Press the OK key <69>, menu 1 appears*
Control panel
Select
from menu levels and selection lists: cursor keys.
Setting
values: Select with the OK key, set with the cursor keys, confirm the setting with the OK key.
Save: You will be asked if you want to save the settings after every dialogue, OK = save, ESC = abort.
Functions of the keys
65
ESC
66
Cursor up
67
Cursor
down
69
OK
Password protection
Various settings are protected against accidental changes by a password. The password is 1000.
All manuals and user guides at all-guides.com
– Deleting an entry
– Move cursor one position to the left
– One level higher in a menu
Scrolling in the menu
Changing a set value
– Confirm/select an input/menu item
– Move cursor one position to the right
48 / 168
24
Datum
12.01.17
Uhrzeit
14:22:35
Rückstau:
ja
Klappe:
geschlossen
Niveau:
aus
Pumpe:
aus
Fig. [21]
65
66
67
ESC
Fig. [22]
69
OK