Changing self-diagnosis interval
A random interval (N days, at xx:xx o'clock) can be set at which the control unit automatically performs a
self-test. The backwater flap is opened and closed, the wastewater pump is switched on. The standard value
corresponds to an SDS interval of 28 days at 8 o'clock.
Changing self-diagnosis interval
Open the operating menu (5.6)
Set and save the self-diagnosis interval under menu item 3.1.1
4.3
Check the potential-free contact
(optional)
Make sure that the functional test has been carried out successfully without checking the potential-free contact in
accordance with Chapter 4.5
Produce an alarm status (Alarm LED flashing) and in each case make sure that the signal is detected at the
potential-free contact. To do so, switch off the mains voltage, alarm status is established, the function can be
checked
4.4
Activate SMS alerting
Proceed as described in the instructions included with this accessory (Kessel TeleControl Modem).
4.5
Carrying out a functional check
Make sure that no error message is pending in the display
Open and close the backwater flap in manual mode (see 5.5.2)
Switch on wastewater pump in manual mode (see 5.5.1)
Optional: Make sure that the following work properly
Potential-free contact
SMS alerting (Kessel TeleControl modem)
Ext. audible alarm
The control unit is ready for operation when all relevant points have been carried out