Télécharger Imprimer la page

Behncke BERLIN 2 Manuel D'utilisation page 58

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
Filter tank BERLIN² / Maintenance
6.12.1 Empty the pool
Switch off the system
Switch off dosing system or similar
Select valve function "Waste".
For pools with automatic level regulation
Switch off magnetic valve.
Open the shut-off valve on the floor drain.
Close the shut-off valve on the surface cleaner.
Switch on the filter pump. The filter pump delivers the water into the sewer.
When the pool is almost empty
Switch off the system.
7
Maintenance
7.1 Safety information on maintenance
Basics
7.2 Maintenance / servicing
Correct maintenance is essential for ensuring the filter system runs faultlessly.
What
Backwash
Manometer pressure check
Water value check
Clean the pump's primary screen
Check the condition and functionality of the
pipes and the system
Check condition and functionality of
electrical devices
22
NOTE
Risk of injury due to maintenance work being carried out improperly!
Improper maintenance may lead to severe injuries or material damage.
Ensure you have sufficient assembly room before starting work.
Make sure that the assembly site is ordered and clean!
Loose components and tools lying on top of and around each other are
sources of accidents.
If components have been removed, ensure correct assembly.
Reinstall all fasteners and
observe screw tightening torque.
When
Weekly
Weekly
Weekly
Monthly
Annually
Annually
NOTE
Agree a maintenance contract with your swimming pool specialist.
Who
Trained person/expert
Trained person/expert
Trained person/expert
Trained person/expert
Expert
Expert

Publicité

loading