general information
EN
1.1
rating plate / lighting instruction location
WARNING
!
•
Allow the appliance to cool before performing any maintenance or cleaning.
Both the rating plate and lighting instructions are attached to a cable and located behind the control panel of the
appliance. Lift the access plate and control panel up and away from the appliance. With the cable at the bulb end of
the slot, wiggle the rating plate out being careful not to tear the instructions.
1.2
mobile home installation
This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
8
W415-4051 / C / 06.29.22
note:
Screen must be removed to access rating plate / lighting instructions.
C
Certified to Canadian and American National Standards: CSA 2.22-2019 / ANSI Z21.50-2019 for Vented Decorative Gas Appliances
Certifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-2019 / ANSI Z21.50-2019 pour les Appareils à gaz décoratif à évacuation
Direct vent, vented gas fireplace. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the current standard CAN / CSA
Z240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. When this US Standard is not
applicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliance must be installed in accordance with local codes, if
any; if none, follow the current ANSI Z223.1 or CSA B149. For use with barrier W565-0264 (Main) / W565-0263 (End). Follow installation instructions.
Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installation conforme aux exigences
de la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280, Manufactured Home Construction and Safety
Standard. Dans le cas ou cette norme d'États-Unis n'est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for Manufactured Home Installations, Sites and Communities. Installer l'appareil
selon les codes ou règlements locaux ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1 ou CSA B149 en vigueur. Utiliser uniquement avec l'écran W565-0264 (Principal)
/ W565-0263 (Fin). Suivre les instructions d'installation.
9700539 (WSL)
BHD4PN
BHD4STN
BHD4PGN
BHD4STGN
BHD4PFCN
BHD4STFCN
Altitude
Input
Reduced Input
C
P4
Manifold Pressure: 3.5" w.c. (NG)
Minimum Supply Pressure: 4.5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: 3,5" d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 4,5" d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 7"* d'une colonne d'eau (GN)
*Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials:
Top, sides & back: per standoff spacers for framing materials. For
finishing materials, see installation instructions.
Top 0"
Floor 0"
Vent top 3"
Vent sides & bottom 2"
Mantel 8"**
**Maximum horizontal extension: 2". See installation
manual for greater extensions, minimum vent lengths and
maximum vent lengths.
This illustration is for reference only. Refer to the rating plate on the appli-
MAX SIZE: 8.5" X 4.75"
HOLE IS 0.250"
Ø
/ 0.312" FROM EDGES
ance for accurate information.
CLASS III
A-2, PERMANENT LABEL, WATERPROOF, 0.010 IN. VELVET MATTE LEXAN AND/OR 0.050 IN. HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUM
MATERIAL:
TEMPERATURE OF 175°F (79°C).
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2
POINT LEADING SPACING OR EQUIVALENT.
note:
BLACK LETTERING ON WHITE BACKGROUND.
SERIAL NUMBERS TO BE ASCENDING FROM BHD4
The rating plate must remain with the appliance at all times. It must not be
WOLF STEEL LTD.
removed.
TITLE: LABEL, RATING PLATE
REVISION: C - Updated year of standard, P4 (PG1) (CN20983) || 02.18.20_P.H.
4001658 (NAC)
4001657 (NGZ)
4001659 (WUSA)
MODEL / MODÈLE
CBHD4PN
BHD4PP
CBHD4PP
CBHD4STN
BHD4STP
CBHD4STP
CBHD4PGN
BHD4PGP
CBHD4PGP
CBHDSTGN
BHD4STGP
CBHD4STGP
BHD4PFCP
BHDSTFCP
0-4500ft (0-1370m)
Élévation
30,000 BTU/h
Alimentation
23,000 BTU/h
Alimentation Réduite
60.9% (See Thru) / 67.8% (Peninsula)
P4
Manifold Pressure: 10" w.c. (P)
Minimum Supply Pressure: 11" w.c. (P)
Maximum Supply Pressure: 13" w.c. (P)
Pression au Collecteur: 10" d'une colonne d'eau (P)
Pression d'Alimentation Min.: 11" d'une colonne d'eau (P)
Pression d'Alimentation Max.: 13" d'une colonne d'eau (P)
*Pression d'alimentation maximale ne devait pas dépasser 13".
Dégagements minimaux des matériaux combustibles:
Dessus, côtés et arrière: selon les espaceurs de dégagement
pour les matériaux d'ossature. Pour les matériaux de finition,
Sides 0"
suivre les instructions d'installation.
Back 0"
Côtés 0"
Dessus 0"
Vertical vent 1"
Arrière 0"
Plancher 0"
Conduit d'évent vertical 1"
Dessus du conduit d'évent 3"
Côtés et dessous du conduit d'évent 2"
Tablette 8"**
**L'extension horizontale maximale: 2". Référez au manuel d'installation pour des
extensions plus grandes, les longueurs d'évacuation minimaux et maximum.
WOLF STEEL LTD. 24 Napoleon Rd. Barrie, Ontario L4M 0G8 Canada
005814
BHD4
REFERENCE# 161746
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF
HEAT, NOT INTENDED FOR USE AS A HEATING APPLIANCE,
NOT FOR USE WITH SOLID FUEL. THIS VENTED GAS
APPLIANCE IS NOT FOR USE WITH AIR FILTERS.
APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N'EST PAS
UNE SOURCE DE CHALEUR; N'EST PAS DESTINÉ À ÈTRE
UTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NE
CONVIENT PAS AUX COMBUSTIBLES SOLIDES. CET
APPAREIL À GAZ N'EST PAS POUR L'USAGE AVEC LES
FILTRES D'AIR.
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE
CERTIFIÉES AVEC L'APPAREIL.
WARNING
:
Do not add any material to the appliance which will come in contact with the
flames, other than that supplied by the manufacturer with the appliance.
AVERTISSEMENT
:
N'ajoutez pas à cet appareil aucun matériau devant entretien
contact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.
The appliance must be vented using the appropriate Napoleon vent kits. See installation
manual for venting specifications. Proper reinstallation and resealing is necessary after servicing
the vent-air intake system.
L'appareil doit être ventilé à l'aide de l'ensemble d'évacuation propre à Napoleon. Référez au
manuel d'installation pour les spécifications d'évacuation. Il est nécessaire de bien réinstaller et
resceller l'évacuation après avoir executer l'entretien du système de prise d'air.
Electrical rating: 115V, 60HZ. Less than 12 amperes.
Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.
BHD4
Serial Number / N° de Série:
W385-1936 / C
PAGE 1 OF 2
DWG#: W385-1936
DATE: 02.28.14
20.1