Télécharger Imprimer la page

Continental Fireplaces Builder Serie Manuel D'installation Et D'utilisation page 45

Publicité

Les langues disponibles

Les langues disponibles

11.9
non-combustible facing material
WARNING
!
Non-combustible facing material must not project more than 4" (101.6mm) from the face of the door (all four
sides). If greater projections are desired, increase the clearance to the sides, bottom and top by 2" (50.8mm) for
every additional 1" (25.4mm) of projection. If using an optional surround, the same rule applies, starting from the
top of the surround. Ensure clearances are maintained for surround removal, as it must lift off the appliance for
maintenance.
A
A
4"
(101.6mm)
2" (50.8mm)
Optional
surround
Section A - A
WARNING
!
Non-combustible facing material must not project more than 4" (101.6mm) from the face of the d
sides). If greater projections are desired, increase the clearance to the sides, bottom and top by
every additional 1" (25.4mm) of projection. If using an optional surround, the same rule applies, s
top of the surround. Ensure clearances are maintained for surround removal, as it must lift off the
maintenance.
B
A
B
A
4"
6" (152.4mm)
(101.6mm)
5" (127mm)
3"(76.2mm)
2" (50.8mm)
4" (101.6mm)
Top of
appliance
Door
Optional
surround
Section A - A
6" (152.4mm)
5" (127mm)
4" (101.6mm)
2" (50.8mm)
Top of
0" (0mm)
appliance
Door
Section B - B
44.4
W415-4051 / C / 06.29.22
finishing
EN
B
B
6" (152.4mm)
3"(76.2mm)
2" (50.8mm)
5" (127mm)
0" (0mm)
4" (101.6mm)
Top of
appliance
Door
Section B - B
44.4
45
6"
5"
4"

Publicité