8

Technical data

Heat
Flame Only
Standby
Batteries Remote
Water Consumption
Inlet Water Pressure
Water Connection
9
Troubleshooting and fault codes remote control
Code
Symptom
The flame effect will not
start.
51
e-BoX will not start or
stopped working and
the LED's continuously
to blink twice.
56
e-BoX will not operate,
the LED's continuously
to blink four times.
24 <
<
<
<
230 V
240 V
1373 W
1495 W
463 W
504 W
32 W
35 W
(2x) 1,5 AA V
0,3 L/h
0,5-8 Bar
½ or ¾ Inch
Cause
No power supply.
Low water level.
The transducers) are not
connected properly.
Low water level.
The absorption valve
(overflow protection) is
activated.
Water filling time is too
long.
Action
Check if power supply is connected to
wall socket correctly and the mains
switch is in the ON (I) position. See fig.
3.0-A.
See "First time water fill", Chapter 4 in
the user manual.
Check that the connector(s) is inserted
correctly, see fig. 3.2.
See "First time water fill", chapter 4 in
the user manual.
Switch the mains switch to the "OFF"
(0) position, see fig. 3.0-A. Check all
connections on water leakage and
the mains switch back in the "ON"
position.
See section 7.2.
Press the mains switch to the "OFF" (0)
position, see fig. 3.0-A.
Check all connections on water leakage.
Close the ball valves and check the
mesh filter by unscrewing the base of it
to see that it is not clogged with dirt
and debris. Open the ball valves again
and turn the mains switch back in the
"ON" (I) position.
turn