Installation manual e-BoX 1000/450 I ST
The flame effect is too
low on the highest
setting.
The flame effect is too
high and there is too
much smoke.
Attention at start-up (15
min) condensation is
possible at the front
glass.
Remote is not working.
Large amount of smoke
appears grey or
colourless.
57
e-BoX will not operate,
the LED's continuously
to blink three times.
58
e-BoX will not operate,
the LED's continuously
to blink once every eight
seconds.
25 <
<
<
<
The transducers and/or air
filter are dirty.
Front glass of warm air
outlet side swapped with
other front glass (e-BoX ST)
Fire image is set to
maximum.
Ambient temperature too
low in the room.
The humidity level is too
high in the room.
Low batteries.
Remote isn't paired to
receiver.
Distance to fire is too far.
Lamp failure.
Water leak
Water level too high.
See chapter 7.
Change the front glasses.
Set the fire image by using the ECO
remote to a lower setting.
Heat the room.
Ventilate the room.
Place new batteries, see chapter 5 in
user manual.
Pair the remote control with the
receiver, see chapter 5 in user manual.
Shortens the distance.
Replace circuit board with lamps.
Press the mains switch to the "OFF" (0)
position, see fig. 3.0-A. Check all
connections on water leakage and
the mains switch back in the "ON"
position.
Switch the mains switch to the "OFF"
(0) position, see fig. 3.0-A and call for
maintenance.