11 Troubleshooting and fault codes remote control
Code
Symptom
The flame effect will not
start.
51
e-MatriX will not start or
stopped working and the
LED's continuously to blink
twice.
56
e-MatriX will not operate,
the LED's continuously to
blink four times.
The flame effect is too low
on the highest setting.
The flame effect is too high
and there is too much
smoke.
32 <
<
<
<
230 V
240 V
2050 W
2250 W
1150 W
1350 W
245 W
260 W
5 W
5 W
(2x) 1,5 AA V
0,15 L/h
0,5-8 Bar
½ or ¾ Inch
Cause
No power supply.
Low water level.
The transducers are not con-
nected properly.
Low water level.
The absorption valve (overflow
protection) is activated.
Water filling time is too long.
The transducers and/or air fil-
ter are dirty.
The extractor fan doesn't work
anymore.
Action
Check if power supply is connected to wall
socket correctly and the mains switch of the
Control box is in the ON (I) position.
See
"First time water fill", chapter 4 in the
user manual.
Check that the connector(s) is inserted cor-
rectly, see fig. 7.1.
See "First time water fill", chapter 4 in the
user manual.
Press the mains switch of the Control box to
the "OFF" (0) position, see fig. 4.0-D. Check
all connections on water leakage and
the mains switch back in the "ON" (I) posi-
tion.
See section 9.2.
Press the mains switch of the Control box to
the "OFF" (0) position, see fig. 4.0-D.
Check all connections on water leakage.
Close the ball valves and check the mesh fil-
ter (fig. 5.0-F) by unscrewing the base of it
to see that it is not clogged with dirt and de-
bris. Open the ball valves again and turn the
mains switch back in the "ON" (I) position.
See chapter 9.
Check if the fan, mounted at the top right in-
side the fire, is running.