Installation

Flush installation

For the flush installation of the induction
glass
ceramic
dimension must be increased to 7 mm!
The distance between the cut-out edge and the
rear and side walls must be minimum 50 mm.
For practical reasons, we recommend a distance of
at least 100 mm between the outmost section edge
and the sidewall.
For installation in built-in kitchen units, ensure
that the plastic or veneer of the units is applied
with
heat-resistant
otherwise
become
especially at the edges.
Seal the exposed cut-out edge with a sealant
such as
silicone.
■ Please observe the manufacturer's instructions
of your worktop regarding its suitability.
wok
PIW 1,
the
seam
adhesive
as
it
might
loose
or
deformed,
Cut-out dimensions
for the installation of
cooktops or for
cooktops and BORA
cooktop extractor fans
beside each other:
Between all build-in appliances, spacing of
1 mm is intended.
Install the installation rail supplied with your
appliance between the BORA built-in appliances or
the appliance and the BORA cooktop extractor fan.
Please observe the installation instructions
on page 27!

Ventilation

■ The front cross-strip of
the cabinet is to be
removed so that a
ventilation opening is
created beneath the
worktop over the whole
width of the appliance.
■ Any
cabinet
cross-
strips that there might be in the area of the
worktop cutout are to be removed.
g
Worktop
cut-out
A
374
346
1
2
745
717
3
1116
1088
485
457
1
1
2
1
856
828
3
2
1338
1310
1709
1681
4
2
B